Goodman / Amana / Daikin GMS8 / GDS8 Furnace Codes

Applies to: Goodman / Amana / Daikin GMS8 / GDS8 (80% single-stage: GMS8, GDS8, Amana AMS8, ADSS8, Daikin VMS8, VDS8). Single red diagnostic LED on the integrated control: PCBBF123(S) or PCBBF134.

CodeMeaningWhat to check
NoneNo signal: furnace doesn't run.No 115 V or 24 V at the control (disconnect off, door switch open, 24 V wires loose), blown fuse or breaker, or an internal control fault. Check for shorts in the 115 V and 24 V circuits. On the PCBBF123, check the 3 A control fuse (replace only with a 3 A automotive fuse). How to fix →
Steady onNormal operation.None.
1 flashLockout after too many ignition retries (3 total).Failure to establish flame (no gas, pressure switch stuck open, bad igniter or alignment, wrong orifices, coated or oxidized flame sensor) or loss of flame (interrupted gas, lazy flames from gas pressure or flue/combustion air restriction, weak inducer). Goodman also lists an open auxiliary limit, which is wired in series with the gas valve. On the PCBBF134 it adds not enough air over the heat exchanger (filters, ductwork, blower speed, failed blower) and a power interruption during the heat cycle that opened the auxiliary limit. How to fix →
2 flashesPressure switch circuit closed while the inducer isn't running.Inducer pressure switch contacts sticking, or a short in the pressure switch circuit. How to fix →
3 flashesPressure switch circuit not closed with the inducer running; inducer runs continuously.Pressure switch hose blocked, pinched or misconnected; blocked flue, inlet pipe or drain, or a weak inducer; wrong setpoint or bad contacts; loose wiring. PCBBF134: also an open manual reset limit on a masonry vent kit (MVK), if installed; inspect the masonry chimney and flue. How to fix →
4 flashesPrimary limit open; circulator blower runs continuously.Faulty primary limit; not enough air over the heat exchanger (blocked filters, restrictive ductwork, wrong blower speed, failed blower); loose wiring. How to fix →
5 flashesFlame sensed with no call for heat; inducer and circulator run continuously.Short to ground in the flame sense circuit (sensor or wiring).
6 flashesRollout limit open (PCBBF134: or the control fuse is blown).Flame rollout, misaligned burners, blocked flue or inlet pipe, failed inducer, loose wiring, or a faulty rollout limit. PCBBF134 adds: a short in the 24 V control or safety circuits, check the heat exchanger and the orifice plate / heat exchanger shield position, and replace the 3 A control fuse if blown. How to fix →
7 flashesLow flame sense microamp signal (furnace still runs).Coated or oxidized sensor, sensor out of position, or lazy flame from wrong gas pressure or combustion air. Clean the sensor (steel wool per Goodman), check alignment, compare gas pressure with the rating plate. How to fix →
8 flashesProblem with the igniter circuit (PCBBF134).Improperly connected or bad igniter, poor unit or burner ground, or a faulty control. Check the wiring, compare igniter resistance with spec, check the ground wiring; replace the control if the rest checks out. How to fix →
C (continuous flashing)115 V or 24 V polarity reversed.115 V polarity reversed at the furnace or control, the transformer wires reversed (orange and gray on the PCBBF123 table, red and blue on the PCBBF134 table), or a poor unit ground.

How to read the codes

Codes point to a circuit, not a part. Test before replacing anything, and never jumper a limit, rollout or pressure switch to keep a furnace running. Gas and line-voltage work is for trained technicians.

Source: Goodman/Amana/Daikin 80% Single Stage Gas Furnaces GMS8, AMS8, GDS8, ADSS8, VMS8, VDS8 Service Instructions RS6612006 Rev. 7 (2017), Troubleshooting: PCBBF123(S) pp. 43-44, PCBBF134 pp. 45-47. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.