York TI Board Furnace Codes
Johnson Controls also sells furnaces under the Coleman and Luxaire names. Codes match only when the control board is the same, so check the board's part number and the label inside the blower door.
| Code | Meaning | What to check |
|---|---|---|
| Steady off | No power to the board. | 24 VAC, fuse. How to fix → |
| Green heartbeat | Normal function, no flame detected (2 seconds on, 2 off). | |
| Amber heartbeat | Normal function, flame detected (first-stage heat on two-stage boards). 2 seconds on, 2 off. | |
| Long amber heartbeat | Two-stage boards: normal function, flame detected, second-stage heat (3.5 seconds on, 0.5 off). | |
| Rapid amber flash | Dirty flame probe: may soon prevent ignition and cause a retry lockout. The heartbeat (2 or 3.5 seconds) flashes rapidly, then 2 seconds off. | Clean the flame probe and verify more than 3.0 VDC on the test pads with a meter. How to fix → |
| 3 amber | Two-stage boards: W2 present without W1. Stored once per power cycle. | Thermostat, control wiring. How to fix → |
| 4 amber | Y present with no G. Stored once per power cycle. | Thermostat, control wiring. How to fix → |
| Steady on red | Control failure, or board not properly tested. | Reset power. If it faults again, replace the control. |
| Rapid red flash | Single-stage boards: incorrect 24 V phasing or twinning error. | 24 VAC R and C connections; twinned furnaces must be on the same line phase. |
| 1 red | Flame present with gas off. Stored. | Gas valve, wiring. How to fix → |
| 2 red | Pressure switch stuck closed (first-stage pressure switch on two-stage boards). Stored. | Pressure switch (first stage), wiring. How to fix → |
| 3 red | Pressure switch stuck open (first-stage pressure switch on two-stage boards). Stored once per call on W. | Pressure switch (first stage), ventor motor. How to fix → |
| 3 double red | Two-stage boards: second-stage pressure switch stuck open. Stored. | Pressure switch (second stage), ventor motor. How to fix → |
| 4 red | Limit switch opened 5 times in 1 call for heat. Stored. | Main limit, blower, filter. How to fix → |
| 5 red | Rollout switch open. Stored; hard lockout. | Rollout switch, overfired. How to fix → |
| 6 red | Pressure switch cycle lockout. Stored; one-hour soft lockout. | Same as code 3. How to fix → |
| 7 red | Ignition lockout due to retries. Stored; one-hour soft lockout. | Gas flow, pressure, valve; flame sensor. How to fix → |
| 8 red | Ignition lockout due to recycles. Stored; one-hour soft lockout. | Same as code 7. How to fix → |
| 9 red | Grounding or line polarity fault. | L1 and neutral, connections, transformer ground, flame probe. |
| 10 red | MV/MV1 failure: gas valve energized with W off. Stored. | First-stage gas valve, wiring. |
| 10 double red | Two-stage boards: MV2 failure. Stored. | Second-stage gas valve, wiring. |
| 11 red | Main blower failure. Stored; hard lockout. | Main blower, limit switch. How to fix → |
| 2 green | No active error codes stored (LAST ERROR pressed between 1/5 and 5 seconds). | |
| 3 green | Stored error codes cleared (LAST ERROR pressed more than 5 seconds). |
How to read the codes
- Boards covered: single stage 031-01972-000 (TI 6DT-1) for builder models G*9S, and 031-01973-000 (TI 6DT-2) for next-generation models PS9 and F*9S; two stage 031-09117-000 (TI 6MD-1) for models PT9, PV9, F*9T and F*9V, all motors. York's note: variable speed motor applications use it with the CFM board 031-09118-000 (TI 6MI-1).
- Push the LAST ERROR button for between 1/5 and 5 seconds to see stored codes; 2 green flashes means none are stored. Hold it more than 5 seconds to clear them; 3 green flashes confirms. These green flashes show only when the furnace isn't heating or cooling.
- In the chart, a code marked stored goes into the error code memory. 3 and 4 amber are stored only once per power cycle; 3 red only once per call on W. Soft lockout lasts one hour; hard lockout is marked separately.
Source: York Service Tips ST-045-09 (September 2, 2009), Generation Before - TI Boards fault code sheet, p. 7. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.
Related
- How to read furnace LED flash codes
- Furnace pressure switch troubleshooting
- Flame sensor microamps and cleaning
Other brands
- Lennox Merit ML180UH (80% single-stage)
- Carrier 58CVA / 58CVX (80% variable-speed two-stage)
- ICP (Heil, Tempstar, Comfortmaker, Arcoaire) N9MSE (90% single-stage condensing, PSC blower)
- ICP (Heil, Tempstar, Comfortmaker, Arcoaire) N8MSN / N8MSL (80% single-stage, PSC blower)
- ICP (Heil, Tempstar, Comfortmaker, Arcoaire) N80ESU / R80ESU (80% single-stage, ECM blower, Ultra Low NOx, minor series 2 and 3)
- ICP (Heil, Tempstar, Comfortmaker, Arcoaire) N80MSU (80% single-stage, ECM blower, Ultra Low NOx, 3-digit display, minor series 3)
- Rheem / Ruud R96V / 96MDV (96% two-stage communicating)
- Rheem / Ruud R97V (97% modulating communicating, downflow/horizontal)
- Rheem / Ruud R98V (98% modulating communicating, upflow)
- Goodman / Amana GR9S80 / GD9S80 (80% single-stage)
- Trane / American Standard S9X1 / S9X2 / S9B1 (96% condensing)
- Lennox SL280UHV (80% two-stage variable speed)
- Goodman / Amana / Daikin GM9S96 / GC9S96 / GM9S92 (96% and 92% condensing, single-stage)
- Carrier 59TP6C two-stage condensing with InteliSense (Performance series)
- Lennox G60DF / G60DFV (older two-stage SureLight boards 18M3401, 46M9901, 18M9901, 49M5901)
- Lennox G60UH / G60UHV (SureLight boards 100869 and 100870)
- Rheem / Ruud R801T Ultra Low NOx (14 ng/J) single-stage upflow/horizontal, constant-torque blower
- Rheem / Ruud 802V / 80MDV (80% two-stage communicating, ECM blower; model numbers (-)802V and (-)(-)80MDV)
- Trane / American Standard S8B1 / S8X1 / S8X2 (80% single-stage and two-stage)
- Trane / American Standard A801X060AM3S (80% single-stage, 2024 installation manual)
- Trane / American Standard A801X (80% single-stage: A801X040AM3SD, A801X040BM2SD, A801X060BM4SD, A801X080BM4SD, A801X080CM5SD, A801X100CM5SD, A801X120DM5SD)
- Goodman / Amana GMVC96 / GCVC96 (96% two-stage variable-speed, *MVC96*BA and *CVC96*BA)
- Goodman / Amana GMVS96 / AMVS96 U-revision (96% variable-speed with analog pressure sensor, model numbers GMVS96*U and AMVS96*U)
- Goodman / Amana GMVM96 / GCVM96 / AMVM96 / ACVM96 (96% modulating, model numbers *MVM96 and *CVM96)
- Rheem / Ruud R801T / 80MSX (80% single-stage, constant-torque blower; model numbers (-)801T and (-)(-)80MSX)
- Rheem / Ruud 802P / 80MDP (80% two-stage, model numbers (-)802P and (-)(-)80MDP)
- Rheem / Ruud 802T / 80MDT (80% two-stage with constant-torque blower, model numbers (-)802T and (-)(-)80MDT)
- Rheem / Ruud 801S / 801P / 80MSS / 80MSP (80% single-stage, model numbers (-)801S, (-)801P, (-)(-)80MSS and (-)(-)80MSP)
- Rheem / Ruud W801T (Rheem Select 80% downflow single-stage)
- Rheem / Ruud R951T (95% single-stage condensing, constant-torque blower; model numbers (-)951T)
- Rheem / Ruud 801V Ultra Low NOx (80% communicating, constant CFM blower, upflow/horizontal)
- Carrier 58STA / 58STX (80% single-stage, 4-way multipoise)
- Carrier 58CTA / 58CTX (80% two-stage, 4-way multipoise, Series 140/E)
- York TG9S (95.5% AFUE single-stage PSC, multi-position)
- York TM9V (96% AFUE two-stage variable-speed ECM, multi-position)
- York UTEC Board (single- and two-stage furnaces from August 2009; SAP 539617, 542760, 542767, 542766; Source 1 S1-33102956000, S1-03102951001, S1-33102954000, S1-33102955000)
- York White-Rodgers Board (the generation before the 2009 UTEC boards; 265901, S1-33109167000 / 265902, S1-33109168000 / 265903, S1-33109169000 / 265904)
- Carrier 58SB0A / 58SB1A (single-stage, non-condensing)