Payne PG9YAA / PG9YAB Furnace Codes

Applies to: Payne PG9YAA / PG9YAB (95% single-stage condensing, direct or non-direct vent). Status LED on the furnace control board.

Payne is a Carrier brand. The PG9YAA (IM-PG9YAA-04, p. 42) and PG9YAB (IM-PG9YAB-03, p. 44) instructions print the same Control Board Diagnostic Codes table. These single-digit flash codes are not the same as the two-digit status codes on most Carrier and Bryant furnaces.

CodeMeaningWhat to check
OFFLED off: 24 VAC or 115 VAC is off, or the fuse is open. How to fix →
ON / SOLIDSoft lockout: furnace control error (1 hour delay).If the code repeats immediately after a power reset, replace the control.
1Not used.
2Pressure switch(es) closed when they should be open. How to fix →
3Pressure switch open when it should be closed. How to fix →
4Limit or rollout switch open (less than 2 minutes). How to fix →
5Flame sensed out of sequence.
6Failure to ignite, or flame sense lost while running.Flame sense current should be at least 0.7 microamps DC (2.0-4.0 nominal). How to fix →
6+1Soft lockout: maximum ignition trials reached (3 hour delay). How to fix →
7Soft lockout: limit or rollout switch open longer than two minutes (1 hour delay).The rollout switch needs a manual reset. How to fix →
8Permanent lockout: gas valve relay contact stuck closed, or a miswired gas valve.Clears with a power reset only.
10Line voltage (115 VAC) polarity reversed.If the furnace is twinned, see the twinning kit instructions.

How to read the codes

Codes point to a circuit, not a part. Test before replacing anything, and never jumper a limit, rollout or pressure switch to keep a furnace running. Gas and line-voltage work is for trained technicians.

Source: Payne PG9YAB Installation Instructions IM-PG9YAB-03, Control Board Diagnostic Codes p. 44 (read at 300 dpi); same table in IM-PG9YAA-04 p. 42. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.