Home / Charts / Trane / American Standard furnace codes

Trane / American Standard A801X Furnace Codes

Applies to: Trane / American Standard A801X (80% single-stage: A801X040AM3SD, A801X040BM2SD, A801X060BM4SD, A801X080BM4SD, A801X080CM5SD, A801X100CM5SD, A801X120DM5SD). Seven-segment display on the integrated furnace control (IFC).

Uses the same integrated furnace control codes as the S8 series, without the second-stage codes. The A801X060AM3S has a different control and its own chart.

CodeMeaningWhat to check
E01Loss of the IRQ or other internal failures (internal IFC error).
E2.1Retry exceeded: flame never sensed. One-hour lockout after 3 times. How to fix →
E2.2Recycles exceeded: flame sensed then lost. One-hour lockout after 10 times. How to fix →
E2.31st-stage gas valve not energized when it should be, exceeded after 10 times. How to fix →
E3.1Shorted pressure switch, 1st stage. How to fix →
E3.2Open pressure switch, 1st stage.On the A801X the pressure switch is connected to the hot header; the manual says to disregard tubing connected to the inducer. Verify pressure switch wiring and tube routing. How to fix →
E04Open limit (main thermal, rollout switch, or reverse airflow switch). How to fix →
E05Flame detected, should not be present. How to fix →
E6.1Voltage reversed polarity.
E6.2Bad grounding.
E6.3Igniter relay fails, or igniter open. How to fix →
E7.11st-stage gas valve (MVL) is energized when it should be off.
E08Flame current is low, but still strong enough to allow operation. How to fix →
E111st-stage gas valve not energized when it should be, or 1st-stage gas valve relay stuck closed. How to fix →
E12Open fuse. How to fix →

How to read the codes

Codes point to a circuit, not a part. Test before replacing anything, and never jumper a limit, rollout or pressure switch to keep a furnace running. Gas and line-voltage work is for trained technicians.

Source: Trane Installation, Operation, and Maintenance, A801X single-stage gas furnaces, A801X-SVX001-1D-EN (August 2024), Integrated Furnace Control Display Codes, pp. 48-49. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.