Goodman / Amana GMVM96 / GCVM96 / AMVM96 / ACVM96 Furnace Codes

Applies to: Goodman / Amana GMVM96 / GCVM96 / AMVM96 / ACVM96 (96% modulating, model numbers *MVM96 and *CVM96). Dual seven-segment display on the integrated control module.

The * in the model number is the brand letter (G for Goodman, A for Amana). The later GMVM97 / GCVM97 has its own instructions; check them before using this chart.

CodeMeaningWhat to check
IFIntegrated control module has an internal fault.Wiring and stable power to the furnace and control; replace the control if it persists.
E0Lockout due to an excessive number of ignition retries or flame recycles (3 total).Gas supply, front cover pressure switch, igniter, orifices, flame sensor, flue and combustion air piping, inducer. How to fix →
E1Low stage pressure switch circuit is closed at the start of the heating cycle.Sticking switch contacts or a short in the switch wiring. How to fix →
E2Low stage pressure switch circuit is not closed. Inducer runs continuously with no furnace operation.Switch hose, blocked flue or inlet pipe, blocked drain, weak or stopped inducer, switch set point, wiring, blocked H fitting port. How to fix →
E3Primary limit open. Circulator blower runs continuously.Filters, restrictive ductwork, circulator speed or failed blower motor, wiring. How to fix →
E4Flame sensed when it should not be present. Inducer and circulator run continuously.Short to ground in the flame sense circuit, lingering burner flame, slow-closing gas valve. How to fix →
E5Open fuse.Short in the low voltage wiring. Fix it, then replace the fuse with a 3-amp automotive type. How to fix →
E6Flame sense micro amp signal is low (furnace still operates).Coated or mispositioned flame sensor; lazy flame from gas pressure or combustion air. How to fix →
E7Igniter fault or improper grounding.Igniter, its wiring and the unit ground. How to fix →
E8High stage pressure switch circuit is closed at the start of the heating cycle. Furnace runs on low stage only.Sticking switch contacts or a short in the switch wiring. How to fix →
E9High stage pressure switch circuit is not closed. Furnace runs on low stage only.Switch hose, flue and inlet piping, drain, inducer, switch set point, wiring. How to fix →
EAPolarity of 115 volt AC is reversed.Line polarity and unit ground.
ECInducer motor overcurrent fault.Reset power and confirm the inducer runs properly; replace the inducer or the control if needed.
EdManual reset rollout switch is open.Orifice plate out of position, blocked heat exchanger, burners out of alignment, defective heat exchanger. How to fix →
EFOpen auxiliary input.Missing jumper between aux in and aux out, or an open float switch. How to fix →
d0Data not yet on network: the furnace has no shared data.Populate the shared data set using the memory card for this model.
d4Invalid memory card data.Confirm the shared data set is right for the model; reload with the correct memory card.
b0Circulator blower motor is not running when it should be running.Motor power leads, the inductor (3/4 and 1 hp models), the motor.
b1Integrated control module has lost communications with the circulator blower motor.Motor control leads, motor, then the control.
b2Circulator blower motor horsepower in the shared data set does not match the motor.Motor horsepower for this model; reload shared data with the correct memory card.
b3Circulator blower motor is operating in a power, temperature, or speed limiting condition.Blocked filters, restrictive or undersized ductwork, high ambient temperature. How to fix →
b4Circulator blower motor senses a loss of rotor control or high current.Filters, grilles, registers, ducts and the furnace air inlet and outlet for blockage. How to fix →
b5Circulator blower motor fails to start 10 consecutive times.Obstruction in the blower housing, seized bearings, failed motor.
b6Circulator blower motor shuts down for over or under voltage, or for over temperature on the power module.Line voltage against the rating plate; high ambient temperature.
b7Circulator blower motor does not have enough information to operate properly, or fails to start 40 consecutive times.Control populated with the correct shared data; locked rotor.
b9Airflow is lower than demanded.Blocked filters, restrictive or undersized ductwork. How to fix →

How to read the codes

Codes point to a circuit, not a part. Test before replacing anything, and never jumper a limit, rollout or pressure switch to keep a furnace running. Gas and line-voltage work is for trained technicians.

Source: Goodman Installation Instructions for *MVM96 and *CVM96 modulating gas furnaces, IO-406E (5/13), Troubleshooting Codes and Status Codes, pp. 52-57. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.