Carrier 58CVA / 58CVX Furnace Codes

Applies to: Carrier 58CVA / 58CVX (80% variable-speed two-stage). Amber LED on the furnace control, two-digit status codes.

Similar two-digit status codes are used on many Carrier, Bryant and Payne furnaces of the same era, but titles and causes vary by model. Check the service label on the blower door.

CodeMeaningWhat to check
11No previous code.
12Blower on after power up.
13Limit circuit lockout.A limit or rollout switch stayed open. Usually airflow; rollout needs a heat exchanger and vent check. How to fix →
14Ignition lockout.Failed to light after repeated tries: gas supply, igniter, flame sensor, gas valve. How to fix →
15Blower motor lockout.
21Gas heating lockout.
22Abnormal flame-proving signal.Flame sensed when the gas valve should be off. How to fix →
23Pressure switch did not open. How to fix →
24Secondary voltage fuse is open.Short in the 24 VAC wiring, thermostat or outdoor unit wiring. How to fix →
25Model selection or setup error.
31High-heat pressure switch or relay did not close or reopened.Vent and intake blockage, hoses, inducer, condensate. How to fix →
32Low-heat pressure switch did not close or reopened.Vent and intake blockage, hoses, inducer, condensate. How to fix →
33Limit circuit fault.A limit opened briefly. If open more than 3 minutes it becomes code 13. How to fix →
34Ignition-proving failure.Weak flame signal: clean the flame sensor, check ground and gas pressure. How to fix →
41Blower motor fault.
43Low-heat pressure switch open while high-heat pressure switch is closed. How to fix →
45Control circuitry lockout.

How to read the codes

Codes point to a circuit, not a part. Test before replacing anything, and never jumper a limit, rollout or pressure switch to keep a furnace running. Gas and line-voltage work is for trained technicians.

Source: Carrier 58CVA/58CVX Troubleshooting Guide, 58-5T (Catalog 535-80107). The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.