Goodman / Amana GR9S80 / GD9S80 Furnace Codes

Applies to: Goodman / Amana GR9S80 / GD9S80 (80% single-stage). Three-character seven-segment display on the integrated control.

Also sold as Amana AR9S80/AD9S80 and Daikin VR9S80/VD9S80. Igniter-circuit, polarity and grounding codes also exist on this control; see the manual linked below for those.

CodeMeaningWhat to check
EE0Lockout due to an excessive number of ignition retries (3 total).Gas supply, igniter, flame sensor, flue blockage, inducer. How to fix →
EE1Pressure switch closed at the start of the heating cycle.Stuck switch contacts or a short in the switch wiring. How to fix →
EE2Pressure switch circuit is not closed.Blocked flue, weak inducer, pinched or blocked hose, wiring. How to fix →
EE3Primary (high) limit circuit is open.Airflow: filters, ductwork, blower speed and motor. How to fix →
EE4Flame sensed with no call for heat.Short at the flame sensor or wiring, or a lingering flame from a slow-closing gas valve. How to fix →
EE5Open fuse.Short in the low-voltage wiring. How to fix →
EE6Low flame sense signal.Clean the flame sensor, check its position and gas pressure. How to fix →
EEbGas valve is not energized when it should be.Wiring to the gas valve; replace the control if wiring is good. How to fix →
EECGas valve is energized when it should not be.Wiring at the gas valve; replace the control if wiring is good.
E11Open rollout switch.Gas pressure, burner alignment, flue and heat exchanger. Manual reset. How to fix →
EEnIgniter open.Igniter wiring and igniter resistance. How to fix →
EEJInducer relay error.Replace the integrated control.
EEHTwinning error.Twinning wiring between furnaces.
EEEInternal fault or IRQ loss in the control.Replace the integrated control.
EbLBlower motor drawing very little current.Loose motor connections, failed motor.
EbUBlower motor drawing too much current.Motor wiring and voltage, seized or failing motor.
EAFLost communication with the R-32 (A2L) refrigerant sensor; furnace in mitigation mode.Sensor wiring; verify the sensor is installed and not damaged.
EALR-32 sensor detected a refrigerant leak; furnace in mitigation mode.Find and repair the leak. The furnace resumes after the leak clears plus a 5-minute delay.
EASR-32 sensor has detected a fault; furnace in mitigation mode.Check and replace the R-32 sensor.
EArA2L relay in the furnace control has detected a fault.Cycle power; replace the control if it persists.

How to read the codes

Codes point to a circuit, not a part. Test before replacing anything, and never jumper a limit, rollout or pressure switch to keep a furnace running. Gas and line-voltage work is for trained technicians.

Source: Goodman Service and Troubleshooting, 80% Single Stage Gas Furnaces, RS6621301 (11/2023). The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.