Rheem / Ruud R951T Furnace Codes

Applies to: Rheem / Ruud R951T (95% single-stage condensing, constant-torque blower; model numbers (-)951T). Seven-segment display on the furnace control.

The (-) in the model number stands for the brand prefix. Two-stage and modulating 90%+ furnaces (R96V, R97V) use longer code lists; see their own charts where we have them.

CodeMeaningWhat to check
101 hour lockout. How to fix →
11Failed ignition. How to fix →
12Low flame sense. How to fix →
13Flame lost. How to fix →
14Unexpected flame.Gas valve leaking through or a shorted flame sense circuit. How to fix →
20Twinning fault.
22Main limit open. How to fix →
26Line and neutral reversed.Swap line and neutral.
33MRLC (manual reset limit control, also called rollout) open. How to fix →
55Pressure switch stuck closed when it should be open. How to fix →
57Pressure switch stuck open when it should be closed. How to fix →
58Water sense circuit open.The condensate (blocked drain) sensor circuit is open. Check the sensor wiring and connections.
59Water sensed.Condensate is backing up. Check the drain trap, drain line and hoses for blockage, and that the furnace is level or tilted as the manual requires.
61Blower fault: blower unable to run.
93Internal control fault.

How to read the codes

Codes point to a circuit, not a part. Test before replacing anything, and never jumper a limit, rollout or pressure switch to keep a furnace running. Gas and line-voltage work is for trained technicians.

Source: Rheem Installation Instructions, 95% 4-position condensing single-stage gas furnaces with constant-torque blower, 92-24161-120-29, Table 17 fault code list, p. 87. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.