Rheem / Ruud R951T Furnace Codes
The (-) in the model number stands for the brand prefix. Two-stage and modulating 90%+ furnaces (R96V, R97V) use longer code lists; see their own charts where we have them.
| Code | Meaning | What to check |
|---|---|---|
| 10 | 1 hour lockout. | How to fix → |
| 11 | Failed ignition. | How to fix → |
| 12 | Low flame sense. | How to fix → |
| 13 | Flame lost. | How to fix → |
| 14 | Unexpected flame. | Gas valve leaking through or a shorted flame sense circuit. How to fix → |
| 20 | Twinning fault. | |
| 22 | Main limit open. | How to fix → |
| 26 | Line and neutral reversed. | Swap line and neutral. |
| 33 | MRLC (manual reset limit control, also called rollout) open. | How to fix → |
| 55 | Pressure switch stuck closed when it should be open. | How to fix → |
| 57 | Pressure switch stuck open when it should be closed. | How to fix → |
| 58 | Water sense circuit open. | The condensate (blocked drain) sensor circuit is open. Check the sensor wiring and connections. |
| 59 | Water sensed. | Condensate is backing up. Check the drain trap, drain line and hoses for blockage, and that the furnace is level or tilted as the manual requires. |
| 61 | Blower fault: blower unable to run. | |
| 93 | Internal control fault. |
How to read the codes
- 0 means standby with no faults. Letters show the current call: C cooling or heat-pump heat, H gas heat, F continuous fan.
- Two-digit codes show the first digit for one second, then the second for one second, then a half-second pause. Each fault shows at least twice, even if it has already cleared.
- Two faults alternate, with the top segment of the display lit for half a second between them.
Source: Rheem Installation Instructions, 95% 4-position condensing single-stage gas furnaces with constant-torque blower, 92-24161-120-29, Table 17 fault code list, p. 87. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.
Related
- How to read furnace LED flash codes
- Furnace pressure switch troubleshooting
- Flame sensor microamps and cleaning
Other brands
- Lennox Merit ML180UH (80% single-stage)
- Carrier 58CVA / 58CVX (80% variable-speed two-stage)
- Rheem / Ruud R96V / 96MDV (96% two-stage communicating)
- Goodman / Amana GR9S80 / GD9S80 (80% single-stage)
- Trane / American Standard S9X1 / S9X2 / S9B1 (96% condensing)
- Lennox SL280UHV (80% two-stage variable speed)
- Goodman / Amana / Daikin GM9S96 / GC9S96 / GM9S92 (96% and 92% condensing, single-stage)
- Carrier 59TP6C two-stage condensing with InteliSense (Performance series)
- Lennox G60DF / G60DFV (older two-stage SureLight boards 18M3401, 46M9901, 18M9901, 49M5901)
- Lennox G60UH / G60UHV (SureLight boards 100869 and 100870)
- Rheem / Ruud R801T Ultra Low NOx (14 ng/J) single-stage upflow/horizontal, constant-torque blower
- Rheem / Ruud 802V / 80MDV (80% two-stage communicating, ECM blower; model numbers (-)802V and (-)(-)80MDV)
- Trane / American Standard S8B1 / S8X1 / S8X2 (80% single-stage and two-stage)
- Trane / American Standard A801X060AM3S (80% single-stage, 2024 installation manual)
- Trane / American Standard A801X (80% single-stage: A801X040AM3SD, A801X040BM2SD, A801X060BM4SD, A801X080BM4SD, A801X080CM5SD, A801X100CM5SD, A801X120DM5SD)
- Goodman / Amana GMVC96 / GCVC96 (96% two-stage variable-speed, *MVC96*BA and *CVC96*BA)
- Goodman / Amana GMVS96 / AMVS96 U-revision (96% variable-speed with analog pressure sensor, model numbers GMVS96*U and AMVS96*U)
- Goodman / Amana GMVM96 / GCVM96 / AMVM96 / ACVM96 (96% modulating, model numbers *MVM96 and *CVM96)
- Rheem / Ruud R801T / 80MSX (80% single-stage, constant-torque blower; model numbers (-)801T and (-)(-)80MSX)
- Rheem / Ruud 802P / 80MDP (80% two-stage, model numbers (-)802P and (-)(-)80MDP)
- Rheem / Ruud 802T / 80MDT (80% two-stage with constant-torque blower, model numbers (-)802T and (-)(-)80MDT)
- Rheem / Ruud 801S / 801P / 80MSS / 80MSP (80% single-stage, model numbers (-)801S, (-)801P, (-)(-)80MSS and (-)(-)80MSP)
- Rheem / Ruud W801T (Rheem Select 80% downflow single-stage)
- Rheem / Ruud 801V Ultra Low NOx (80% communicating, constant CFM blower, upflow/horizontal)
- Carrier 58STA / 58STX (80% single-stage, 4-way multipoise)
- Carrier 58SB0A / 58SB1A (single-stage, non-condensing)
Did you find your code?
One field tip a week
A short, practical HVAC tip in your inbox every week: diagnostics, charging, airflow and code changes. Free, unsubscribe anytime.
We'll only use your email for the newsletter. Privacy policy.
HVAC Cheat Sheet · Free PT charts, code lookups and calculators for techs at hvaccheatsheet.com