Rheem / Ruud R801T Ultra Low NOx Furnace Codes

Applies to: Rheem / Ruud R801T Ultra Low NOx (14 ng/J) single-stage upflow/horizontal, constant-torque blower. Seven-segment display on the furnace control.

Ultra Low NOx models only (model numbers ending in MUA or similar). The standard R801T has a shorter code list; see its own chart.

CodeMeaningWhat to check
101-hour lockout. How to fix →
11Failed ignition. How to fix →
12Low flame sense. How to fix →
13Flame lost. How to fix →
14Unexpected flame.Gas valve leaking through or a shorted flame sense circuit. How to fix →
22Main or auxiliary limit open. How to fix →
26L1 and neutral reversed.Swap line and neutral.
33Rollout switch open. How to fix →
34Induced draft motor overcurrent.
42Flame LED not detected.
43Ignition pressure switch closed when it should be open. How to fix →
55Combustion pressure switch closed when it should be open. How to fix →
56Ignition pressure switch open when it should be closed. How to fix →
57Combustion pressure switch open when it should be closed. How to fix →
58Water sensor jumper not attached.
61Blower fault.
71Inducer fault.
74Gas inlet pressure switch open.Check inlet gas pressure.
75Venturi air inlet pressure switch open.
93Control fault (hard lockout).
96Flame circuit fault. How to fix →
97Gas valve circuit fault.

How to read the codes

Codes point to a circuit, not a part. Test before replacing anything, and never jumper a limit, rollout or pressure switch to keep a furnace running. Gas and line-voltage work is for trained technicians.

Source: Rheem Installation Instructions, (-)801T Upflow Series Ultra Low NOx single-stage gas furnaces, 92-24161-164-01, Diagnostics. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.