ICP (Heil, Tempstar, Comfortmaker, Arcoaire) N80MSU Furnace Codes
International Comfort Products builds furnaces sold under several brand names, including Heil, Tempstar, Comfortmaker and Arcoaire. The N80MSU uses a newer control with a 3-digit display and two-part codes (major.minor), a pressure transducer and an inducer RPM signal, so its codes don't match the older N80ESU, N8MSN or N9MSE charts. Go by the service label on the furnace you're working on.
| Code | Meaning | What to check |
|---|---|---|
| 10.1 | L1 polarity fault (LED flashes rapidly). | Line voltage polarity reversed at the furnace. |
| 12.1 | W on at power-up or within 5 minutes. | Thermostat and W wiring. |
| 13.1 | Limit lockout: a switch opened in the limit circuit. | How to fix → |
| 14.1 | Ignition lockout after 4 consecutive ignition tries. | How to fix → |
| 14.2 | Flame lost 3 times after 70 seconds of heating. | How to fix → |
| 14.3 | 7 loss-of-flame events during a heat request, or three 34.4 faults during a heat request. | How to fix → |
| 14.4 | Lockout: 7 loss-of-pressure events during a heat request. | How to fix → |
| 21.1 | 24 VAC sensed on the gas valve when it shouldn't be. | |
| 22.1 | False flame. | |
| 23.3 | Pressure detected over 0.15 in. w.c. (about 0.65 V DC signal to ground; 0 in. = about 0.500 V DC). | The transducer reads pressure when it shouldn't. Check the pressure tubing and the transducer. How to fix → |
| 24.1 | Fuse fault. | Find the short in the 24 V wiring before replacing the fuse. How to fix → |
| 25.1 | No program information in the micro. No heating operation. | Reprogram the control with the correct program number from the rating plate; replace the control if the problem remains. |
| 25.2 | Corrupted program file. No heating operation. | Reprogram the control using the service app or a super plug (supplied separately). |
| 25.3 | Twinned units are not identical (program numbers don't match). The main unit will not heat. | Twinned furnaces must be identical, with the same program number. |
| 25.4 | Main program invalid; using the backup program. The control still operates normally. | Reprogram the control to correct it. |
| 25.5 | Installer settings corrupted. The control runs on default installer settings. | Reselect the installer settings or reprogram the control. |
| 25.6 | Wrong program for the control. No heating operation. | Reprogram the control so the program matches the control used. |
| 26.1 | Lockout: BTS (burner thermal switch) open. Power reset only. | Find out why the burner area overheated before resetting power. How to fix → |
| 27.1–27.3 | Program in the super plug missing, not recognized or corrupted. | Remove the super plug and retry. If code 27 remains, try a different super plug. If it still fails, replace the control. |
| 31.4 | Loss of pressure before the blower comes on. | How to fix → |
| 31.5 | Loss of pressure after the blower comes on. | How to fix → |
| 34.1 | Ignition fault during four consecutive ignition trials. | How to fix → |
| 34.2 | Flame lost after successful ignition (flame proven), before the heating blower on-delay. | How to fix → |
| 34.3 | Flame lost after successful ignition (flame proven), after the heating blower on-delay. | How to fix → |
| 34.4 | Flame lost while operating at reduced inducer pressure after a previous 34.3 fault. | How to fix → |
| 42.1 | No inducer RPM feedback at start-up or before ignition is proved. | How to fix → |
| 42.2 | No inducer RPM feedback after ignition is proved. | How to fix → |
| 42.3 | Exceeding the inducer RPM limit (model specific). | How to fix → |
| 45.1 | Control failure: flame circuit fault, memory mismatch or sequence error. | Cycle power. If code 45 repeats, replace the control. |
| 45.2 | Control failure: gas valve relay will not close. | Cycle power. If code 45 repeats, replace the control. |
| 45.3 | Control failure: EEPROM memory issue. | Cycle power. If code 45 repeats, replace the control. |
| 46.1 | Momentary loss of power. |
How to read the codes
- The display shows the major code in the first two digits and the minor code in the third (for example 34.2). The status LED shows only the major code: the first digit is the number of short flashes and the second the number of long flashes (34 = 3 short, 4 long).
- Normal status displays: idL idle, Ht heating, CL1 low cooling, CL2 high cooling, HPd heat pump defrost (gas heat running during a heat pump defrost), CFn continuous fan, bLr secondary furnace of a twinned pair running its blower. ##.# means an active status code.
- The display shows the system status after start-up or when no button has been pressed for 60 seconds. The menu (MENU/SELECT and NEXT/OPTION buttons) includes FLt, the last 7 faults.
- Component test: the furnace must be idle (idL) with no thermostat call on W, Y or G. Select Ct from the menu. The inducer comes on and stays on, the hot surface igniter comes on for 15 seconds after a 10-second wait, then the blower for 10 seconds, then the inducer runs 10 more seconds and the test ends.
- The blower access door switch removes 115 V from the control. Manufacturer's warning: don't tape or defeat it; hold it in with one hand while using the buttons with the other, and don't touch uninsulated electrical parts.
Source: ICP N80MSU Installation, Start-up, Operating and Service and Maintenance Instructions, N80MSU-03SI: Table 11 p. 22, Fig. 35 Service Label p. 24. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.
Related
- How to read furnace LED flash codes
- Furnace pressure switch troubleshooting
- Flame sensor microamps and cleaning
Other brands
- Lennox Merit ML180UH (80% single-stage)
- Carrier 58CVA / 58CVX (80% variable-speed two-stage)
- ICP (Heil, Tempstar, Comfortmaker, Arcoaire) N9MSE (90% single-stage condensing, PSC blower)
- ICP (Heil, Tempstar, Comfortmaker, Arcoaire) N8MSN / N8MSL (80% single-stage, PSC blower)
- ICP (Heil, Tempstar, Comfortmaker, Arcoaire) N80ESU / R80ESU (80% single-stage, ECM blower, Ultra Low NOx, minor series 2 and 3)
- Rheem / Ruud R96V / 96MDV (96% two-stage communicating)
- Rheem / Ruud R97V (97% modulating communicating, downflow/horizontal)
- Rheem / Ruud R98V (98% modulating communicating, upflow)
- Goodman / Amana GR9S80 / GD9S80 (80% single-stage)
- Trane / American Standard S9X1 / S9X2 / S9B1 (96% condensing)
- Lennox SL280UHV (80% two-stage variable speed)
- Goodman / Amana / Daikin GM9S96 / GC9S96 / GM9S92 (96% and 92% condensing, single-stage)
- Carrier 59TP6C two-stage condensing with InteliSense (Performance series)
- Lennox G60DF / G60DFV (older two-stage SureLight boards 18M3401, 46M9901, 18M9901, 49M5901)
- Lennox G60UH / G60UHV (SureLight boards 100869 and 100870)
- Rheem / Ruud R801T Ultra Low NOx (14 ng/J) single-stage upflow/horizontal, constant-torque blower
- Rheem / Ruud 802V / 80MDV (80% two-stage communicating, ECM blower; model numbers (-)802V and (-)(-)80MDV)
- Trane / American Standard S8B1 / S8X1 / S8X2 (80% single-stage and two-stage)
- Trane / American Standard A801X060AM3S (80% single-stage, 2024 installation manual)
- Trane / American Standard A801X (80% single-stage: A801X040AM3SD, A801X040BM2SD, A801X060BM4SD, A801X080BM4SD, A801X080CM5SD, A801X100CM5SD, A801X120DM5SD)
- Goodman / Amana GMVC96 / GCVC96 (96% two-stage variable-speed, *MVC96*BA and *CVC96*BA)
- Goodman / Amana GMVS96 / AMVS96 U-revision (96% variable-speed with analog pressure sensor, model numbers GMVS96*U and AMVS96*U)
- Goodman / Amana GMVM96 / GCVM96 / AMVM96 / ACVM96 (96% modulating, model numbers *MVM96 and *CVM96)
- Rheem / Ruud R801T / 80MSX (80% single-stage, constant-torque blower; model numbers (-)801T and (-)(-)80MSX)
- Rheem / Ruud 802P / 80MDP (80% two-stage, model numbers (-)802P and (-)(-)80MDP)
- Rheem / Ruud 802T / 80MDT (80% two-stage with constant-torque blower, model numbers (-)802T and (-)(-)80MDT)
- Rheem / Ruud 801S / 801P / 80MSS / 80MSP (80% single-stage, model numbers (-)801S, (-)801P, (-)(-)80MSS and (-)(-)80MSP)
- Rheem / Ruud W801T (Rheem Select 80% downflow single-stage)
- Rheem / Ruud R951T (95% single-stage condensing, constant-torque blower; model numbers (-)951T)
- Rheem / Ruud 801V Ultra Low NOx (80% communicating, constant CFM blower, upflow/horizontal)
- Carrier 58STA / 58STX (80% single-stage, 4-way multipoise)
- Carrier 58CTA / 58CTX (80% two-stage, 4-way multipoise, Series 140/E)
- York TG9S (95.5% AFUE single-stage PSC, multi-position)
- York TM9V (96% AFUE two-stage variable-speed ECM, multi-position)
- York UTEC Board (single- and two-stage furnaces from August 2009; SAP 539617, 542760, 542767, 542766; Source 1 S1-33102956000, S1-03102951001, S1-33102954000, S1-33102955000)
- York White-Rodgers Board (the generation before the 2009 UTEC boards; 265901, S1-33109167000 / 265902, S1-33109168000 / 265903, S1-33109169000 / 265904)
- York TI Board (older furnaces; 031-01972-000 TI 6DT-1, 031-01973-000 TI 6DT-2, 031-09117-000 TI 6MD-1, 031-09118-000 TI 6MI-1)
- Carrier 58SB0A / 58SB1A (single-stage, non-condensing)