York White-Rodgers Board Furnace Codes
Johnson Controls also sells furnaces under the Coleman and Luxaire names. Codes match only when the control board is the same, so check the board's part number and the label inside the blower door.
| Code | Meaning | What to check |
|---|---|---|
| Steady off | No power to the board. Fault codes are possible with a blown on-board fuse. | How to fix → |
| Green heartbeat | Normal operation, no call for heat. | |
| 1 amber | Normal operation with call for heat (first stage on two-stage boards). | |
| 2 amber | Two-stage boards: normal operation with call for second-stage heat. | |
| 3 amber | Two-stage boards: W2 present with no W1. | How to fix → |
| 4 amber | Y present with no G call. | How to fix → |
| Rapid amber flash | Low flame sense current. | How to fix → |
| Solid red | Internal gas valve error, micro and frequency check. | |
| Rapid red flash | Twinning error, incorrect 24 V phasing. | |
| 1 red | Flame sensed when no flame should be present. Stored. | How to fix → |
| 2 red | Pressure switch stuck closed, or inducer error. Stored. | How to fix → |
| 3 red | First-stage pressure switch stuck open, or inducer error. Stored. | How to fix → |
| 3 double red | Two-stage boards: second-stage pressure switch stuck open, or inducer error. Stored. | How to fix → |
| 4 red | Open limit switch. Stored. | How to fix → |
| 5 red | Open rollout or open fuse detected. Stored; hard lockout. | How to fix → |
| 6 red | Pressure switch cycle lockout. Stored; one-hour soft lockout. | How to fix → |
| 7 red | External lockout (retries). Stored; one-hour soft lockout. | How to fix → |
| 8 red | External lockout (recycles). Stored; one-hour soft lockout. | How to fix → |
| 9 red | Grounding or reversed polarity, or transformer leads reversed. | |
| 10 red | Gas flow with no call for heat. Stored. | |
| 11 red | Limit switch open more than 5 minutes (blower failure). Stored; hard lockout. | How to fix → |
| 12 red | Igniter failure. | How to fix → |
How to read the codes
- Boards covered: single stage (265901, and S1-33109167000 / 265902), two-stage PSC motor (S1-33109168000 / 265903), and two-stage variable speed ECM motor (S1-33109169000 / 265904).
- To read stored codes, push and release the LAST ERROR button for more than 1/5 second and less than 5 seconds. The LED flashes up to five stored codes, newest first, with 2 seconds between codes. Two green flashes means no codes are stored. Solid LED codes are not stored or shown.
- To clear stored codes, push and hold LAST ERROR for at least five seconds. The LED flashes three green when memory is cleared.
- In the chart, a code marked stored goes into the error code memory. Soft lockout lasts one hour; hard lockout is marked separately.
- York's 2009 service tip says the UTEC board can replace these boards, except that the single-stage PSC UTEC board has no CONT FAN SPEED and no second-stage cooling. For those, York pointed to the existing W/R board, P/N S1-3310916700, while supplies lasted, or a switching relay such as S1-S90-370 for two stages of cooling.
Source: York Service Tips ST-045-09 (September 2, 2009), Last Generation W/R Emerson IFC Boards fault code sheet, p. 6, and p. 1. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.
Related
- How to read furnace LED flash codes
- Furnace pressure switch troubleshooting
- Flame sensor microamps and cleaning
Other brands
- Lennox Merit ML180UH (80% single-stage)
- Carrier 58CVA / 58CVX (80% variable-speed two-stage)
- ICP (Heil, Tempstar, Comfortmaker, Arcoaire) N9MSE (90% single-stage condensing, PSC blower)
- ICP (Heil, Tempstar, Comfortmaker, Arcoaire) N8MSN / N8MSL (80% single-stage, PSC blower)
- ICP (Heil, Tempstar, Comfortmaker, Arcoaire) N80ESU / R80ESU (80% single-stage, ECM blower, Ultra Low NOx, minor series 2 and 3)
- ICP (Heil, Tempstar, Comfortmaker, Arcoaire) N80MSU (80% single-stage, ECM blower, Ultra Low NOx, 3-digit display, minor series 3)
- Rheem / Ruud R96V / 96MDV (96% two-stage communicating)
- Rheem / Ruud R97V (97% modulating communicating, downflow/horizontal)
- Rheem / Ruud R98V (98% modulating communicating, upflow)
- Goodman / Amana GR9S80 / GD9S80 (80% single-stage)
- Trane / American Standard S9X1 / S9X2 / S9B1 (96% condensing)
- Lennox SL280UHV (80% two-stage variable speed)
- Goodman / Amana / Daikin GM9S96 / GC9S96 / GM9S92 (96% and 92% condensing, single-stage)
- Carrier 59TP6C two-stage condensing with InteliSense (Performance series)
- Lennox G60DF / G60DFV (older two-stage SureLight boards 18M3401, 46M9901, 18M9901, 49M5901)
- Lennox G60UH / G60UHV (SureLight boards 100869 and 100870)
- Rheem / Ruud R801T Ultra Low NOx (14 ng/J) single-stage upflow/horizontal, constant-torque blower
- Rheem / Ruud 802V / 80MDV (80% two-stage communicating, ECM blower; model numbers (-)802V and (-)(-)80MDV)
- Trane / American Standard S8B1 / S8X1 / S8X2 (80% single-stage and two-stage)
- Trane / American Standard A801X060AM3S (80% single-stage, 2024 installation manual)
- Trane / American Standard A801X (80% single-stage: A801X040AM3SD, A801X040BM2SD, A801X060BM4SD, A801X080BM4SD, A801X080CM5SD, A801X100CM5SD, A801X120DM5SD)
- Goodman / Amana GMVC96 / GCVC96 (96% two-stage variable-speed, *MVC96*BA and *CVC96*BA)
- Goodman / Amana GMVS96 / AMVS96 U-revision (96% variable-speed with analog pressure sensor, model numbers GMVS96*U and AMVS96*U)
- Goodman / Amana GMVM96 / GCVM96 / AMVM96 / ACVM96 (96% modulating, model numbers *MVM96 and *CVM96)
- Rheem / Ruud R801T / 80MSX (80% single-stage, constant-torque blower; model numbers (-)801T and (-)(-)80MSX)
- Rheem / Ruud 802P / 80MDP (80% two-stage, model numbers (-)802P and (-)(-)80MDP)
- Rheem / Ruud 802T / 80MDT (80% two-stage with constant-torque blower, model numbers (-)802T and (-)(-)80MDT)
- Rheem / Ruud 801S / 801P / 80MSS / 80MSP (80% single-stage, model numbers (-)801S, (-)801P, (-)(-)80MSS and (-)(-)80MSP)
- Rheem / Ruud W801T (Rheem Select 80% downflow single-stage)
- Rheem / Ruud R951T (95% single-stage condensing, constant-torque blower; model numbers (-)951T)
- Rheem / Ruud 801V Ultra Low NOx (80% communicating, constant CFM blower, upflow/horizontal)
- Carrier 58STA / 58STX (80% single-stage, 4-way multipoise)
- Carrier 58CTA / 58CTX (80% two-stage, 4-way multipoise, Series 140/E)
- York TG9S (95.5% AFUE single-stage PSC, multi-position)
- York TM9V (96% AFUE two-stage variable-speed ECM, multi-position)
- York UTEC Board (single- and two-stage furnaces from August 2009; SAP 539617, 542760, 542767, 542766; Source 1 S1-33102956000, S1-03102951001, S1-33102954000, S1-33102955000)
- York TI Board (older furnaces; 031-01972-000 TI 6DT-1, 031-01973-000 TI 6DT-2, 031-09117-000 TI 6MD-1, 031-09118-000 TI 6MI-1)
- Carrier 58SB0A / 58SB1A (single-stage, non-condensing)
Did you find your code?
One field tip a week
A short, practical HVAC tip in your inbox every week: diagnostics, charging, airflow and code changes. Free, unsubscribe anytime.
We'll only use your email for the newsletter. Privacy policy.
HVAC Cheat Sheet · Free PT charts, code lookups and calculators for techs at hvaccheatsheet.com