Rheem / Ruud R801T / 80MSX Furnace Codes

Applies to: Rheem / Ruud R801T / 80MSX (80% single-stage, constant-torque blower; model numbers (-)801T and (-)(-)80MSX). Seven-segment display on the furnace control.

Standard-emissions models. Ultra Low NOx R801T furnaces (14 ng/J) have extra codes; see their own chart.

CodeMeaningWhat to check
101 hour lockout. How to fix →
11Failed ignition. How to fix →
12Low flame sense. How to fix →
13Flame lost. How to fix →
14Unexpected flame.Gas valve leaking through or a shorted flame sense circuit. How to fix →
20Twinning fault.
22Main limit or HALC open. How to fix →
26Line and neutral reversed.Swap line and neutral.
33MRLC (manual reset limit control, also called rollout) open. How to fix →
55Pressure switch stuck closed when it should be open. How to fix →
57Pressure switch stuck open when it should be closed. How to fix →
61Blower fault: blower unable to run.
93Internal control fault.

How to read the codes

Codes point to a circuit, not a part. Test before replacing anything, and never jumper a limit, rollout or pressure switch to keep a furnace running. Gas and line-voltage work is for trained technicians.

Source: Rheem Installation Instructions, (-)801T / (-)(-)80MSX upflow/horizontal single-stage gas furnaces with constant-torque blower, 92-24161-144-01, Diagnostics and Fault Codes, p. 39. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.