Rheem / Ruud 801V Ultra Low NOx Furnace Codes

Applies to: Rheem / Ruud 801V Ultra Low NOx (80% communicating, constant CFM blower, upflow/horizontal). Seven-segment display on the furnace control.

Ultra Low NOx furnaces have an ignition pressure switch, a venturi air inlet switch and a gas inlet pressure switch that standard furnaces don't, so several codes here exist only on this series. Rheem's contractor app gives more detail per code (scan the QR code on the furnace).

CodeMeaningWhat to check
CLInducer speed calibration running.Normal operation, not a fault.
101 hour lockout. How to fix →
11Failed ignition. How to fix →
12Low flame sense. How to fix →
13Flame lost. How to fix →
14Unexpected flame.Gas valve leaking through or a shorted flame sense circuit. How to fix →
22Main / aux limit open. How to fix →
26L1 and neutral reversed.Swap line and neutral.
33Rollout switch open. How to fix →
34Induced draft motor overcurrent. How to fix →
42Flame LED not detected.
43Ignition pressure switch closed when it should be open. How to fix →
55Combustion pressure switch closed when it should be open. How to fix →
56Ignition pressure switch open when it should be closed. How to fix →
57Combustion pressure switch open when it should be closed. How to fix →
58Water sensor jumper not attached.
61Blower fault.
71Inducer fault. How to fix →
74Gas inlet pressure switch open. How to fix →
75Venturi air inlet pressure switch open.
93Control fault.

How to read the codes

Codes point to a circuit, not a part. Test before replacing anything, and never jumper a limit, rollout or pressure switch to keep a furnace running. Gas and line-voltage work is for trained technicians.

Source: Rheem Installation Instructions, 80+ communicating upflow/horizontal Ultra Low NOx gas furnaces with constant CFM/PWM blower, 92-24161-184-04, Fault Codes, p. 42. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.