Rheem / Ruud W801T Furnace Codes

Applies to: Rheem / Ruud W801T (Rheem Select 80% downflow single-stage). Seven-segment display on the furnace control.

Same code list as the upflow 801S / 801P chart. Two-stage furnaces split the pressure switch codes into low and high; see their own charts.

CodeMeaningWhat to check
101 hour lockout. How to fix →
11Failed ignition. How to fix →
12Low flame sense. How to fix →
13Flame lost. How to fix →
14Unexpected flame.Gas valve leaking through or a shorted flame sense circuit. How to fix →
20Twinning fault.
22Main limit or HALC open. How to fix →
26Line and neutral reversed.Swap line and neutral.
33MRLC (manual reset limit control, also called rollout) open. How to fix →
55Pressure switch stuck closed when it should be open. How to fix →
57Pressure switch stuck open when it should be closed. How to fix →
61Blower fault: blower unable to run.
93Internal control fault.

How to read the codes

Codes point to a circuit, not a part. Test before replacing anything, and never jumper a limit, rollout or pressure switch to keep a furnace running. Gas and line-voltage work is for trained technicians.

Source: Rheem Select Installation Instructions for 80% downflow single-stage gas furnaces (W801T), Diagnostics and Fault Codes, p. 35. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.