HVAC glossary

Plain-English definitions for the terms you'll see on service calls and in manuals. Underlined words in our guides and code charts show these definitions when you tap them.

ABCDEFGHILMOPRSTWZ

A2L
A refrigerant safety class meaning lower toxicity and mildly flammable. R-32 and R-454B are A2L, so they need A2L-rated tools and extra install rules. Learn more →
AFUE
Annual Fuel Utilization Efficiency: the share of a furnace's fuel that becomes heat over a season. 96% AFUE means 96 cents of every fuel dollar heats the home.
BTU (BTU/h, BTUH)
British thermal unit, a measure of heat. Equipment capacity is in BTU per hour (BTU/h); 12,000 BTU/h equals 1 ton.
bubble point
For a blend with glide, the temperature where liquid starts to boil. Use it with liquid-line pressure to figure subcooling. Learn more →
C wire (common wire)
The 24-volt common from the transformer. Smart thermostats need it for constant power. Learn more →
CFM
Cubic feet per minute, the amount of air a blower moves. A common target is about 350–400 CFM per ton of cooling. Learn more →
contactor
A heavy-duty relay in the outdoor unit. 24-volt control power on its coil closes contacts that send line voltage to the compressor and fan. Learn more →
DC bus
The high-voltage DC circuit on an inverter board, fed by rectified line voltage. Its capacitors can stay charged after power is off. Learn more →
deep vacuum (evacuation)
Pulling a system down to a few hundred microns to remove air and moisture before charging. Confirm with a micron gauge and a decay test. Learn more →
defrost
A heat pump mode that briefly reverses to melt frost off the outdoor coil in heating. Steam and a paused indoor fan are normal.
dew point
For a blend with glide, the temperature where vapor starts to condense. Use it with suction pressure to figure superheat. Learn more →
EEPROM
A memory chip on a control board that stores settings and model data. EEPROM errors usually mean a board or its data is bad.
EEV (electronic expansion valve)
An expansion valve opened and closed by the control board with a stepper motor, so it can meter refrigerant precisely.
EPA 608
The federal certification required to buy refrigerant and work on sealed refrigerant systems. Learn more →
flame sensor
A metal rod in the burner flame. The board proves flame by measuring a tiny DC current (microamps) through it. Learn more →
flare connection (flare)
A cone-shaped fitting made on the end of copper tubing and tightened onto a threaded nut. The most common leak point on mini-splits. Learn more →
flat-rate pricing (flat rate)
Pricing each task at a fixed price quoted up front, instead of billing hours plus parts. Learn more →
glide (temperature glide)
The difference between a blended refrigerant's bubble and dew points at the same pressure. R-454B has a small glide; R-410A's is nearly zero.
high limit (limit switch, main limit, primary limit)
A safety switch that shuts off the gas if the furnace gets too hot, usually from low airflow. Learn more →
hot surface igniter (HSI, igniter)
A ceramic element that glows hot enough to light the gas. Cracks and white spots mean it's failing. Learn more →
HSPF2
The current heating efficiency rating for heat pumps (2023 test method). Higher is more efficient.
inches of water column (in. w.c., inches w.c., "wc, IWC)
A unit for very low pressures, used for gas pressure and duct static pressure. 1 psi is about 27.7 inches of water column.
inducer (draft inducer, combustion air inducer)
A small blower that pulls combustion gases through the furnace and out the vent before and during burner operation.
inverter
Electronics that turn line power into variable-frequency power so the compressor can speed up and slow down instead of only on and off.
IPM (intelligent power module)
The power module on an inverter board that switches high-voltage DC to drive the compressor. IPM faults point to voltage, airflow, the compressor or the board. Learn more →
latent heat (latent load)
Heat removed by condensing moisture out of the air, as opposed to sensible heat, which changes the air's temperature.
line set
The pair of copper lines (suction and liquid) that connects the indoor and outdoor units. Learn more →
manifold pressure
Gas pressure after the gas valve, at the burners, measured in inches of water column. Must match the rating plate.
Manual J
The ACCA standard method for calculating a home's heating and cooling load, room by room. Learn more →
MERV
A filter efficiency rating from 1 to 16. Higher catches more but can restrict airflow if the duct system isn't sized for it. Learn more →
microamps (µA)
Millionths of an amp. Flame sensor current is measured in microamps; low readings cause flame-loss lockouts.
microfarad (µF, MFD)
The unit capacitors are rated in. A run capacitor should read within its printed tolerance, often ±5% or ±6%.
micron (microns)
A unit of very low pressure used to measure vacuum. Lower is deeper; 500 microns or below is a common target.
O/B
The thermostat terminal that controls a heat pump's reversing valve. O energizes in cooling on most brands; B energizes in heating on some. Learn more →
PCB (control board, circuit board)
Printed circuit board: the electronic control in a furnace, air handler or mini-split.
PFC
Power factor correction: a circuit on inverter boards that smooths how the unit draws power. PFC faults are often supply-voltage problems.
piston (fixed orifice)
A fixed metering device with a single hole. Systems with a piston are charged by superheat. Learn more →
pressure switch
A furnace safety that proves the inducer is moving enough air before ignition. Usually the switch isn't the problem; the venting or inducer is. Learn more →
PT chart
A table showing the temperature at which a refrigerant boils or condenses at each pressure. Learn more →
refrigerant recovery
Removing refrigerant from a system into a recovery cylinder instead of venting it, as federal rules require.
reversing valve (4-way valve, four-way valve)
The valve that switches a heat pump between heating and cooling by changing the direction of refrigerant flow.
rollout switch (flame rollout)
A safety switch near the burners that opens if flame escapes the burner area. Often manual reset. Find the cause before resetting. Learn more →
run capacitor (capacitor)
A part that gives a motor's start winding a phase shift so it starts and runs efficiently. Rated in microfarads (µF). Learn more →
saturation temperature (saturation)
The temperature at which refrigerant boils or condenses at a given pressure. Read it from a PT chart. Learn more →
SEER2
The current cooling efficiency rating for AC and heat pumps (2023 test method). Higher is more efficient.
subcooling
How many degrees the liquid line is below its saturation temperature. Used to check charge on TXV and EEV systems. Learn more →
superheat
How many degrees the suction vapor is above its saturation temperature. Used to check charge on piston systems and evaporator performance. Learn more →
temperature rise
Supply air temperature minus return air temperature on a furnace. It must fall in the range on the rating plate. Learn more →
thermistor
A temperature sensor whose resistance changes with temperature. Test it against the manufacturer's resistance table. Learn more →
ton (tons)
A unit of cooling capacity equal to 12,000 BTU per hour.
total external static pressure (TESP, static pressure)
The resistance the blower works against from the ducts, filter and coil, measured in inches of water column. Learn more →
TXV (thermostatic expansion valve)
A valve that meters refrigerant into the evaporator to hold a steady superheat. Systems with a TXV are charged by subcooling.
wet bulb
Air temperature measured with a wet wick, which reflects humidity. Indoor wet bulb is used to find target superheat.
zero-crossing
A board circuit that watches the AC voltage pass through zero to time fan and power control. Errors usually mean a power or board problem.