Bryant 619AHB/619PHB High Wall Error Codes
Bryant ductless systems come from Carrier. The older 619PHA uses two-character codes (E1, P4); the 619AHB and 619PHB use the four-character codes below. The 619PHB service manual (SM619PHB-01, Table 12 p. 25) prints the same indoor code table and the same diagnosis descriptions and parts lists as the 619AHB manual.
| Code | Meaning | What to check |
|---|---|---|
| EH 00 / EH 0A | Indoor unit EEPROM parameter error (operation lamp 1 flash, timer off). | Indoor PCB. |
| EL 01 | Indoor/outdoor unit communication error (2 flashes). | Interconnect wiring; indoor PCB, outdoor PCB, a short-circuited component. How to fix → |
| EH 02 | Zero-crossing signal detection error (3 flashes). | Connection wires; indoor main PCB. |
| EH 03 | Indoor fan operating outside its normal speed range (4 flashes). | Connection wires, fan assembly, indoor main PCB. |
| EC 51 | Outdoor unit EEPROM parameter error (5 flashes). | Outdoor PCB. |
| EC 52 | T3 (condenser coil) sensor open or shorted (5 flashes). | Connection wires, sensor, outdoor main PCB. How to fix → |
| EC 53 | T4 (outdoor ambient) sensor open or shorted (5 flashes). | Connection wires, sensor, outdoor main PCB. How to fix → |
| EC 54 | TP (compressor discharge) sensor open or shorted (5 flashes). | Connection wires, sensor, outdoor main PCB. How to fix → |
| EC 56 | T2B sensor open or shorted (5 flashes). | Connection wires, sensor, outdoor main PCB. How to fix → |
| EH 60 | T1 (indoor room) sensor open or shorted (6 flashes). | Connection wires, sensor, indoor main PCB. How to fix → |
| EH 61 | T2 (indoor coil) sensor open or shorted (6 flashes). | Connection wires, sensor, indoor main PCB. How to fix → |
| EC 07 | Outdoor fan operating outside its normal speed range (12 flashes). | Connection wires, fan assembly, fan motor, outdoor main PCB. |
| EH 0b | Indoor PCB / display board communication error (9 flashes). | Communication wire, indoor PCB, display board. (The diagnosis page heads this code EH06.) |
| EL 0C | Refrigerant leakage detection (8 flashes). | T2 sensor, indoor PCB, refrigerant charge (leak check). How to fix → |
| PC 00 | IPM malfunction or IGBT over-current (operation lamp 7 flashes, timer flashing). | Wiring, IPM module board, outdoor fan assembly, compressor, outdoor PCB. How to fix → |
| PC 01 | Over voltage or too low voltage protection (2 flashes, timer flashing). | Power supply wires, IPM module board, PCB, reactor. How to fix → |
| PC 02 | Compressor top temperature, or IPM high temperature/high pressure protection (3 flashes, timer flashing). | Connection wires, outdoor PCB, IPM module board, high pressure protector, system blockages. How to fix → |
| PC 03 | Low pressure protection (7 flashes, timer flashing). | Connection wires, outdoor PCB, low pressure protector, refrigerant charge. |
| PC 04 | Inverter compressor drive error (5 flashes, timer flashing). | Connection wires, IPM module board, outdoor fan assembly, compressor, outdoor PCB. How to fix → |
| PC 08 | Current overload protection (1 flash, timer flashing). | Wiring, reactor, outdoor fan, outdoor PCB. |
| PC 40 | Communication error between the outdoor chip and the compressor chip (6 flashes, timer flashing). | Outdoor PCB and IPM module board. How to fix → |
| -- | Indoor units mode conflict (1 flash, timer on). Multi-zone. | Not a part failure: indoor units are calling for opposite modes. |
| EH b1 | Indoor board and multi-function board communication error (9 flashes). | Wiring between the boards; indoor board. |
| FH 0d | Ionizer malfunction (11 flashes). | Ionizer and its wiring. |
How to read the codes
- Check the indoor unit's code first; some indoor codes point to outdoor problems. Codes show as two letters and two characters (for example EH 00, PC 04).
- Operation lamp flash counts repeat across codes (five flashes covers EC 51 to EC 56), so read the display, not only the lamp.
- 619AHB indoor units with only green and red LEDs (Table 4): green on, red off = standby; red on = operating; both on = high/low voltage protection on the compressor terminal; green on, red flashing = EEPROM error; red flashing = compressor speed out of control; green flashing, red on = zero-crossing, lack of phase or synchronization error; green flashing, red off = IGBT or module protection; both flashing = communication error.
- 619AHB outdoor board: LED1 (blue) flashes once a second in standby and twice a second with a fault. Sizes 9K-18K use LED3 green and LED2 red; 24K-36K use LED2 green and LED3 red. Green flashing, red off = IPM or IGBT protection; both on = over/under voltage; green on, red flashing = EEPROM; any other flashing combination = inverter compressor drive error. Bryant's outdoor table lists these as P0, P1, E5 and P4 on the indoor display, the older code style.
- The 'check' column lists the parts Bryant's diagnosis page says to have ready for each code.
Source: Bryant 619AHB Ductless Service Manual SG-619AHB-02, Indoor Unit Diagnostic Guides (Tables 4-5) p. 14, Outdoor Unit Error Display (Tables 6-7) p. 15, Diagnosis and Solution pp. 16-35; same indoor table in Bryant 619PHB Service Manual SM619PHB-01, Table 12 p. 25, diagnosis pp. 26-45. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the unit you're working on.
Related
- Mini-split communication error troubleshooting
- Mini-split flare connections (the usual leak point)
- Ductless mini-split maintenance
- Look up any mini-split code
Other brands
- Daikin FTX / FVXS / FDMQ with RXL outdoor (19 Series)
- Fujitsu Halcyon / Airstage splits (indicator lamp codes)
- MRCOOL DIY E Star 4th Generation
- Mitsubishi Electric MSZ-GL / MSY-GL (failure mode recall)
- Senville AURA / LETO
- LG Single / multi-split wall units (CH codes)
- Gree Livo / All-Match with LIV outdoor (R-32)
- Pioneer Diamante / Quantum (WYT-17, WYT-20, WYT-24, WYT-25, WYT-FA)
- Lennox Mini-splits: MLB / MPC / 3PC outdoor with M22A, M33C, MWMC, MCFA/B, MFMA indoor
- ACiQ Single-zone wall mount, R-454B (ACiQ-xxWS / -xxW-BL with -xxZS / -xxZPL outdoor)
- Midea High wall ductless DLFSHB (DLFSHBH09XAK, -12XAJ, -12XAK, -18XAK, -24XAK)
- Durastar Single-zone wall mount (indoor DRAW09F1A, DRAW12F1A, DRAW18F1A, DRAW24F1A; outdoor DRA1U09S1A, DRA1U12S1A, DRA1U18S1A, DRA1U24S1A)
- Friedrich Floating Air Pro R-454B (single zone; systems FPHW093B, FPHW123B, FPHW183B, FPHW243B; indoor FAHFW09A3A, FAHFW12A3A, FAHFW18A3A, FAHFW24A3A; outdoor FPHSR09A3B, FPHSR12A3B, FPHSR18A3B, FPHSR24A3B)
- Bryant 619PHA high wall ductless (619PHAQ09XA3, 619PHAQ12XA3, 619PHAQ18XA3, 619PHAQ24XA3)
- Bryant 619RE Console and Cassette (floor console 619REQ009FBMA, 619REQ012FBMA; cassette 619REQ009CBMA, 619REQ012CBMA, 619REQ018CBMA)
- Bryant 619RE Console and Cassette (floor console 619REQ009FBMA, 619REQ012FBMA; cassette 619REQ009CBMA, 619REQ012CBMA, 619REQ018CBMA)
- Bryant 619RE Console/Cassette/Ducted (floor console 619REQ009FBMA, 619REQ012FBMA; cassette 619REQ009CBMA, 619REQ012CBMA, 619REQ018CBMA; ducted 619REQ009DBMA, 619REQ012DBMA, 619REQ018DBMA, 619REQ024DBMA, 619REQ036DBMA, 619REQ048DBMA)
- Durastar Multi-zone (outdoor DRA2U18M1A, DRA3U28M1A, DRA4U36M1A, DRA5U48M1A; indoor DRAW, DRAC, DRAD, DRAF and DRAS F1A heads)
- Friedrich Floating Air R-454B (single zone; systems FPHW091C, FPHW121C; indoor FAHSW09A1C, FAHSW12A1C, FAHFW09A1C, FAHFW09A3D, FAHFW12A3D, FAHFW18A3D, FAHFW24A3D; outdoor FPHSR09A1C, FPHSR12A1C, FPHSR09A3D, FPHSR12A3D, FPHSR18A3D, FPHSR24A3D)
- Klimaire KSIE inverter wall mount (2014–2016 models, e.g. KSIE012-H120-SW)
Did you find your code?
One field tip a week
A short, practical HVAC tip in your inbox every week: diagnostics, charging, airflow and code changes. Free, unsubscribe anytime.
We'll only use your email for the newsletter. Privacy policy.
HVAC Cheat Sheet · Free PT charts, code lookups and calculators for techs at hvaccheatsheet.com