Klimaire KSIE inverter wall mount Error Codes

Applies to: Klimaire KSIE inverter wall mount (2014–2016 models, e.g. KSIE012-H120-SW). Indoor display code, or flashes of the Operation lamp with the Timer lamp off, on or flashing.

Newer Klimaire lines show different code sets. Check the series on the indoor unit label before using this table.

CodeMeaningWhat to check
E0Indoor unit EEPROM parameter error (Operation lamp 1 flash, Timer off).Indoor control board.
E1Indoor/outdoor communication error (2 flashes, Timer off).Interconnect wiring, terminal screws, power at the outdoor unit. How to fix →
E2Zero-crossing signal detection error (3 flashes, Timer off).
E3Indoor fan speed out of control (4 flashes, Timer off).Indoor fan motor, blower wheel binding, connector.
E4Indoor room temperature sensor T1 open or shorted (5 flashes, Timer off).Measure the sensor; check the connector. How to fix →
E5Evaporator coil temperature sensor T2 open or shorted (6 flashes, Timer off).Measure the sensor; check the connector. How to fix →
ECRefrigerant leak detected (7 flashes, Timer off).Leak search, starting at the flare connections. How to fix →
F0Overload current protection (1 flash, Timer on).
F1Outdoor ambient temperature sensor T4 open or shorted (2 flashes, Timer on).Measure the sensor; check the connector. How to fix →
F2Condenser coil temperature sensor T3 open or shorted (3 flashes, Timer on).Measure the sensor; check the connector. How to fix →
F3Compressor discharge temperature sensor T5 open or shorted (4 flashes, Timer on).Measure the sensor; check the connector. How to fix →
F4Outdoor unit EEPROM parameter error (5 flashes, Timer on).Outdoor control board.
F5Outdoor fan speed out of control (6 flashes, Timer on).Outdoor fan motor, obstruction, connector.
P0IPM malfunction or IGBT over-strong current protection (1 flash, Timer flashing).Inverter board and compressor. How to fix →
P1Over voltage or low voltage protection (2 flashes, Timer flashing).Supply voltage under load and connections. How to fix →
P2Compressor top high temperature protection, 9k and 12k models (3 flashes, Timer flashing).Charge, outdoor airflow, dirty coil.
P3Outdoor ambient temperature too low (4 flashes, Timer flashing).
P4Inverter compressor drive error (5 flashes, Timer flashing).Compressor wiring, inverter board. How to fix →
P5Indoor units mode conflict, multi-zone only (6 flashes, Timer flashing). Not a failure.

How to read the codes

Codes point to a circuit, not a part. Test before replacing boards or sensors. Inverter boards hold a dangerous charge after power-off; wait and verify DC bus voltage is gone before touching them. Refrigerant work requires EPA 608 certification.

Source: Klimaire KSIE troubleshooting guide (2016), 9.1 Indoor Unit Error Display. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.