Home / Charts / Fujitsu mini-split codes

Fujitsu Halcyon / Airstage splits Error Codes

Applies to: Fujitsu Halcyon / Airstage splits (indicator lamp codes). OPERATION (green), TIMER (orange) and ECONOMY (green) lamps on the indoor unit; two-digit code on a wired remote.

Fujitsu uses one numbering scheme across many systems, but not every code applies to every model. Wall-mount singles mostly show the communication, sensor, fan and outdoor codes.

CodeMeaningWhat to check
11 (1-1)Serial communication error.Interconnect wiring, terminals, splices. How to fix →
12 (1-2)Wired remote controller communication error.
14 (1-4)Network communication error.
15 (1-5)Check run unfinished.
16 (1-6)Transmission / peripheral connection error.
21 (2-1)Refrigerant circuit address setting error.
22 (2-2)Indoor unit capacity error.
23 (2-3)Combination error (indoor/outdoor mismatch).
24 (2-4)Connection unit number error.
26 (2-6)Address setting error.
27 (2-7)Master/slave unit setup error.
29 (2-9)Connection unit number error in wired remote circuit.
31 (3-1)Power supply interruption error.Supply voltage and connections. How to fix →
32 (3-2)Indoor PCB EEPROM error.Indoor control board.
35 (3-5)Manual auto switch error.Stuck manual/auto button.
3A (3-10)Indoor unit wired remote communication error.
41 (4-1)Inlet air temperature sensor error.Measure the thermistor; check connector. How to fix →
42 (4-2)Indoor heat exchanger middle temperature sensor error.Measure the thermistor; check connector. How to fix →
51 (5-1)Indoor unit fan motor error.Fan motor, connector, blower wheel binding.
52 (5-2)Indoor electronic expansion valve error.
53 (5-3)Drain pump error.Drain pump, float, plugged drain.
57 (5-7)Damper error.
58 (5-8)Intake grille error.
5U (5-15)Indoor unit error.
62 (6-2)Outdoor PCB / communication error.
63 (6-3)Inverter error.Inverter board and compressor. How to fix →
64 (6-4)Active filter / PFC circuit error.
65 (6-5)Trip terminal 'L' error.
6A (6-10)Display PCB / communication error.
71 (7-1)Outdoor discharge temperature sensor error.Measure the thermistor; check connector. How to fix →
72 (7-2)Compressor temperature sensor error. How to fix →
73 (7-3)Outdoor heat exchanger liquid temperature sensor error. How to fix →
74 (7-4)Outdoor ambient temperature sensor error. How to fix →
75 (7-5)Outdoor suction refrigerant temperature sensor error. How to fix →
76 (7-6)2/3-way valve temperature sensor error. How to fix →
77 (7-7)Outdoor heat sink temperature sensor error. How to fix →
82 (8-2)Sub-cool inlet/outlet temperature sensor error. How to fix →
83 (8-3)Outdoor liquid pipe temperature sensor error. How to fix →
84 (8-4)Outdoor current sensor error. How to fix →
86 (8-6)High/low pressure sensor or switch error.
94 (9-4)Outdoor current trip detection.Compressor, refrigerant system, supply voltage. How to fix →
95 (9-5)Compressor rotor location detection error.Compressor wiring and inverter output. How to fix →
97 (9-7)Outdoor fan motor error.Outdoor fan motor, obstruction, connector.
98 (9-8)Outdoor fan motor 2 error.
99 (9-9)Four-way valve error.Reversing valve coil and operation.
9A (9-10)Coil (expansion valve) error.
9U (9-15)Outdoor unit error.
A1 (10-1)Outdoor abnormal discharge temperature.Low charge or restriction. How to fix →
A3 (10-3)Abnormal compressor temperature.
A4 (10-4)High pressure error.Dirty outdoor coil, fan, overcharge, restriction.
A5 (10-5)Low pressure error.Low charge (leak), restriction, closed valve. How to fix →

How to read the codes

Codes point to a circuit, not a part. Test before replacing boards or sensors. Inverter boards hold a dangerous charge after power-off; wait and verify DC bus voltage is gone before touching them. Refrigerant work requires EPA 608 certification.

Source: Fujitsu General (UK) Fault Codes reference. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.