Mitsubishi Electric MSZ-GL / MSY-GL Error Codes
Mitsubishi indoor units show faults by blinking the OPERATION INDICATOR lamp. These counts are from the failure mode recall table; the blink counts during a live fault can differ, and outdoor details need the outdoor unit's service manual.
| Code | Meaning | What to check |
|---|---|---|
| Not lit | Normal. | |
| 1 blink (0.5 s) | Room temperature thermistor short or open. | Measure against the thermistor chart in the service manual. How to fix → |
| 2 blinks | Indoor coil thermistor short or open. | Measure against the thermistor chart. How to fix → |
| 3 blinks | Serial signal: no signal from the outdoor unit for up to 6 minutes. | Miswiring, interconnect wiring, outdoor power. How to fix → |
| 11 blinks | Indoor fan motor: no rotation feedback 12 seconds after start. | Fan motor, connector, wheel binding. |
| 12 blinks | Indoor control system: nonvolatile memory can't be read. | Replace the indoor electronic control board. |
How to read the codes
- Count the blinks between the 2.5-second OFF pauses, and watch at least two cycles.
- Failure mode recall reads the stored indoor fault even if it isn't happening now. The procedure is in the indoor unit service manual.
- If recall shows the outdoor unit is at fault, use the outdoor unit's failure mode recall and LED table.
Source: Mitsubishi Electric MSZ-GL/MSY-GL Indoor Unit Service Manual OBH732, Indoor unit failure mode table. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the furnace you're working on.
Related
- Mini-split communication error troubleshooting
- Mini-split flare connections (the usual leak point)
- Look up any mini-split code
Other brands
- Daikin FTX / FVXS / FDMQ with RXL outdoor (19 Series)
- Fujitsu Halcyon / Airstage splits (indicator lamp codes)
- MRCOOL DIY E Star 4th Generation
- Senville AURA / LETO
- LG Single / multi-split wall units (CH codes)
- Gree Livo / All-Match with LIV outdoor (R-32)
- Pioneer Diamante / Quantum (WYT-17, WYT-20, WYT-24, WYT-25, WYT-FA)
- Lennox Mini-splits: MLB / MPC / 3PC outdoor with M22A, M33C, MWMC, MCFA/B, MFMA indoor
- ACiQ Single-zone wall mount, R-454B (ACiQ-xxWS / -xxW-BL with -xxZS / -xxZPL outdoor)
- Midea High wall ductless DLFSHB (DLFSHBH09XAK, -12XAJ, -12XAK, -18XAK, -24XAK)
- Klimaire KSIE inverter wall mount (2014–2016 models, e.g. KSIE012-H120-SW)