EPA 608 Certification in 2026: Types, the New Exam and What Changed
If you open a refrigerant circuit, even just to add refrigerant, you need EPA Section 608 certification. Here's how it's structured and what changed in 2026.
The four sections
| Section | Covers | You need it for |
|---|---|---|
| Core | Regulations, ozone, recovery, safety, shipping | Required with any type |
| Type I | Small appliances (factory-sealed, 5 lb or less), such as window units and refrigerators | Small appliance service |
| Type II | High-pressure appliances, such as residential and commercial AC, heat pumps, most refrigeration | Most HVAC techs |
| Type III | Low-pressure appliances, such as low-pressure chillers | Chiller work |
| Universal | Core + Types I, II and III | Full coverage |
Each section has 25 questions, and you need 70% to pass a section. The test must be given by an EPA-approved certifying organization. A Core section taken open-book can't count toward Universal.
What changed in 2026
- New question bank. EPA and the approved certifying organizations revised the exam for only the second time since it began. The new bank has roughly 400 questions across the four sections, and the format stays the same.
- A2L and A3 refrigerants. New general-knowledge questions cover A2L and A3 refrigerants such as R-32, R-454B and R-1234yf. Questions that used to reference R-22 systems may now use R-32 or R-454B.
- Timing. The new bank came out in August 2026, and exams from the old bank can only be given through January 1, 2027.
- Not covered: the revised exam doesn't test AIM Act regulations. You still need to know them on the job. See our guide to HFC rules for 2026.
If you're already certified
- Your card stays valid. EPA 608 certification doesn't expire, and there's no federal requirement to retake the exam.
- A2L work: there's no separate federal A2L certification. Your 608 covers A2L refrigerants, though many manufacturers, distributors and states expect A2L-specific training.
- Adding a type later: if you hold Type II and want Type I or III, sections taken after January 1, 2027 come from the new bank.
Study tips
- Focus on Core. It's required and it's where most people fail.
- Know the leak-rate thresholds, recovery requirements, recovery cylinder rules and refrigerant safety classes (A1, A2L, A3).
- Take timed practice tests from the new question bank.
FAQ
Does EPA 608 certification expire?
No. Section 608 certification doesn't expire.
Do I need a new certification for R-454B or R-32?
Not at the federal level. Your existing 608 covers them. Check state and local requirements and manufacturer training.
What score do I need to pass?
70% on each section (18 of 25 questions).
Sources
One field tip a week
A short, practical HVAC tip in your inbox every week: diagnostics, charging, airflow and code changes. Free, unsubscribe anytime.
We'll only use your email for the newsletter. Privacy policy.
Tools for this job
Related guides
400 CFM per Ton: Where the Rule Comes From and When It's Wrong
Why 400 CFM per ton is the default cooling airflow, when to set airflow lower or higher, and how to check what a system is actually moving.
AC Compressor Not Starting: Humming, Clicking or Nothing at All
Diagnose a compressor that won't start by what it does: humming points to capacitor or locked rotor, clicking to overload, silence to the control circuit.
AC Not Cooling? A Step-by-Step Diagnostic Checklist for Techs
Work an AC no-cool call in the right order, from the thermostat call to airflow, electrical and refrigerant charge, without guessing.
Condenser Fan Not Spinning: Capacitor, Motor or Control?
Find out why an outdoor condenser fan won't run, from the fan capacitor and seized bearings to the contactor, wiring and heat pump defrost.
Field reference for trained technicians. Always follow the equipment manufacturer's instructions, local code and safe work practices. See our editorial standards, or report a correction.