Scotsman Prodigy Flaker and Nugget Ice Machine Codes
| Code | Meaning | What to check |
|---|---|---|
| F | Freeze (ice making) mode. | Normal operation. |
| F (flashing) | Ice making is pending. | Normal at every restart: the auger motor starts first, and F goes steady once the compressor starts. |
| b | Bin is full. | Normal: the photo-eyes in the chute are blocked by ice. The compressor stops and the auger runs a short time to clear the evaporator. If the bin isn't full but Bin Eyes Blocked is on, check the eyes' position and wipe scale off them. |
| C | Clean cycle. | A de-scale or sanitize cycle is running: the auger runs 20 minutes, then the compressor starts. Press Off to end it. |
| L (flashing) | Board remotely locked out (with all four upper lights flashing). | Locked from outside the machine. Scotsman's cuber label says to contact the leasing company. |
| L | Board locked by button press. | Lock or unlock: hold On for 3 seconds and, still holding, press and release Off twice. |
| d | Test mode. | The test cycle starts and ends on its own. |
| O | Off. | Standby. Press On. |
| E | Self test failed. | The Power light blinks green. Run test mode to see whether the controller switches its loads. |
| 1 (flashing) | No ice sensed, restart mode. | The photo-eyes saw no ice in time (the first 6 minutes are ignored). The machine shuts down for 10 minutes and tries again. |
| 1 | No ice sensed three times in a row; requires manual reset. | Check for ice flowing down the chute; if very little or none is being made, look for a refrigeration failure. Check that the auger motor has power: if not, check the controller's Auger light; if it does, check the motor windings. How to fix → |
| 2 (flashing) | Auger motor over amp, restart mode. | The auger motor drew more than the set limit, so the controller shut off the compressor and auger. It restarts after a set time. |
| 2 | Auger motor over amp three times in a row; requires manual reset. | Check the gear reducer and auger bearings for damage, and check for a restriction between the reservoir and the evaporator. How to fix → |
| 3 | Slow water fill / no water in reservoir. | The controller won't start without water at the sensor (the Water light blinks red). Restore the water supply, check the water filters, the reservoir water level and the water sensor; wipe mineral off the sensor probes. How to fix → |
| 4 | Pressure control open: refrigeration pressure too high or too low. | Both pressure switches reset on their own and the controller restarts the machine. Check the condenser fan and motor, water flow into the evaporator and the refrigerant charge. On remote units the low pressure switch is a pump-down control, so it doesn't show a code. How to fix → |
How to read the codes
- The code display shows a letter or number. Letters F, b, C, L, d and O are normal states; E and the numbers 1 to 4 are diagnostic codes. The list is on the label next to the display (Technician Section). On Prodigy Plus D series the same lights and switches are repeated on the lower panel.
- A flashing 1 or 2 means the machine is retrying. A steady 1 or 2 means it has shut down and must be reset by hand.
- Reset: press and release Off, then press and release On.
- Recall the last 10 codes: from standby, hold Off for 3 seconds and release, then press and release Clean to step from the newest code to the oldest. Clear them: hold Clean and Off together for 3 seconds.
- Test mode: hold Off for 3 seconds, then hold Clean for 3 seconds. The display shows d and the controller switches each load on and off in turn.
- Component lights on the controller: Bin Eyes Blocked (ice in the chute), Water Present (water touching the sensor), Comp and Auger (running). Water Dispense and Ice Dispense aren't used on these models.
Source: Scotsman Prodigy Flaked and Nugget Ice Machines Service Manual, F0522-F1522 and N0422-N1322 including Prodigy Plus D series (December 2014, rev. May 2017), AutoAlert and Display Code p. 21, Control Button Use p. 22, Refrigeration System p. 26, Sensors p. 39, Service Diagnosis p. 40; code list from Scotsman Prodigy Plus D Series Flaker Technical Review 291-853, pp. 4, 7-8. The "meaning" column follows the manufacturer's wording; "what to check" is our field summary. Always go by the label on the unit you're working on.
Related
- Commercial ice machine troubleshooting (no ice, freeze-ups, harvest problems)
- Commercial refrigeration practice test
- Look up any ice machine code
Other brands
- Hoshizaki KM-901M/1100M/1340M/1601M J Series (modular crescent cubers: KM-901M_J, KM-1100M_J, KM-1340M_J, KM-1601MRJ)
- Hoshizaki KM-350/420/520/660M J Series (modular crescent cubers: KM-350MAJ, KM-350MWJ, KM-420MAJ, KM-420MWJ, KM-420MRJZ, KM-520MAJ, KM-520MWJ, KM-520MRJ, KM-520MRJZ, KM-660MAJ, KM-660MWJ, KM-660MRJ, KM-660MRJZ)
- Hoshizaki KM MAK Series (modular crescent cubers: KM-322MAK, KM-330MAK, KM-522MAK, KM-530MAK, KM-622MAK, KM-730MAK, KM-930MAK2, KM-1130MAK2)
- Hoshizaki F MAK Series Flakers (modular flakers and cubelet: F-422MAK, F-622MAK-C, F-622MWK-C, F-622MRKZ-C, F-822MAK, F-822MWK, F-1022MAK, F-1022MWK, F-1022MRKZ, F-1022MLKZ; -C, -SC and -CB cubelet versions)
- Hoshizaki F-1530/2030 MK2 Flakers (modular flakers: F-1530MAK2, F-1530MWK2, F-1530MRKZ2, F-2030MWK2, F-2030MRKZ2, F-2030MRKZ3, F-2030MLKZ; -C and -SC cubelet versions)
- Scotsman Prodigy and Prodigy Plus Cubers (modular cubers C0322, C0522, C0722, C0330, C0530, C0630, C0830, C1030, C1448, C1848, C2148)
- Manitowoc Indigo NXT (air, water and remote cubers and flakers: IDT0300, IDT0420, IDT0450, IDT0500, IDT0620, IDT0750, IDT0900, IDT1200, IDT1500, IDT1900, IYT0300, IYT0420, IYT0450, IYT0500, IYT0620, IYT0750, IYT0900, IYT1200, IYT1500, IYT1900, IRT0500, IRT0620, IRT0750, IRT0900, IRT1900, IDF0300, IDF0500, IDF0600, IDF0900, IYF0300, IYF0500, IYF0600, IYF0900, IRF0900)
Did you find your code?
One field tip a week
A short, practical HVAC tip in your inbox every week: diagnostics, charging, airflow and code changes. Free, unsubscribe anytime.
We'll only use your email for the newsletter. Privacy policy.
HVAC Cheat Sheet · Free PT charts, code lookups and calculators for techs at hvaccheatsheet.com