Gas furnace and heating controls practice test
58 questions. How a gas furnace starts, proves flame and protects itself, plus gas pressure, airflow, 24-volt controls and heat pumps. Practice with every answer explained, or take a 25-question exam. Each answer names its source and links to the guide that teaches it.
58 questions in this set.
What it covers
| Sequence of operation (9) | What a gas furnace does from the call for heat to the post-purge, and how it locks out. |
| Flame sensing and pilots (9) | Flame rectification, microamp readings, intermittent pilots and thermocouples. |
| Safety controls (9) | High limits, rollout switches, pressure switches and delayed ignition. |
| Gas pressure and input (9) | Inlet and manifold pressure, orifices and clocking the meter. |
| Airflow and temperature rise (6) | Temperature rise, CFM math, static pressure and CFM per ton. |
| 24-volt controls (8) | Transformers, board fuses, float switches, igniters and capacitors. |
| Heat pumps and thermostats (8) | O/B, auxiliary and emergency heat, defrost, terminals and cycle rate. |
Study first
- Furnace sequence of operation and normal cycle timing
- Flame sensor microamps by manufacturer
- Checking inlet and manifold gas pressure
- Temperature rise and airflow
- Rollout switches
- Auxiliary and emergency heat
More practice tests
AC charging and refrigeration
43 questions. Superheat and subcooling, PT charts, TXVs, evacuation, leak finding, A2L refrigerants, brazing and the AIM Act leak rules.
ELECHVAC electrical
32 questions. Capacitors, contactors, compressor winding tests, PSC and ECM motors, and diagnosing units that won't start.
REFRCommercial refrigeration
28 questions. Walk-in superheat and TD, electric and hot gas defrost, condensing unit maintenance, reach-ins and ice machine alarms.
RTURooftop units and economizers
25 questions. Rooftop start-up, voltage imbalance, scroll rotation, economizer changeover and setpoints, economizer alarms and Carrier ComfortLink alerts.
HYDRBoilers and hydronics
23 questions. Zone valves and switching relays, expansion tanks and relief valves, air elimination, circulators and boiler short cycling.
DUCTMini-splits
27 questions. Line set length and added charge, flare torque, triple evacuation, test run, communication faults, thermistors, inverter board safety and cleaning.
EPAEPA 608
Core, Type I, II and III, with study guides for each section.
FAQ
Is this an official NATE, school or certification test?
No. These are original questions written by HVAC Cheat Sheet. Every specific number comes from a manufacturer manual, regulation or trade reference named under the answer, and each question links to the guide that covers it.
Who is it for?
HVAC students, apprentices and newer technicians preparing for heating in school, a certification exam or their first winter in the field. Instructors are welcome to use it in class.
Do the numbers apply to every furnace?
No. Questions that quote timings, pressures or microamps say which manufacturer and model they come from. On the job, the rating plate and installation manual for the unit in front of you always win.
Does it save my progress?
Your best scores and missed questions are saved in your browser on this device. Nothing is sent to us, and there's no signup.
One field tip a week
A short, practical HVAC tip in your inbox every week: diagnostics, charging, airflow and code changes. Free, unsubscribe anytime.
We'll only use your email for the newsletter. Privacy policy.
Original practice questions by HVAC Cheat Sheet, written from the documents named under each answer. Not affiliated with NATE or any school or testing organization. Found an error or want a topic added? Tell us.