Furnace Pressure Switch Checker

Tee a manometer into the pressure switch hose, run the inducer, and enter what you read along with the setpoint printed on the switch. The checker tells you whether the switch should be closed, so you know whether to replace the switch or go after the vent, trap, hose or inducer.

in. w.c.
in. w.c.
in. w.c.

Find what the board's flash code means in the furnace code charts.

How it decides

  • Pressures are compared as magnitudes, since furnace switches are usually printed as negative values (for example −0.65 in. w.c.).
  • Draft at or above the setpoint: the switch should be closed. If it's open, the switch (or the hose and port right at it) is the problem.
  • Draft below the setpoint: the switch is right to stay open. The cause is upstream: venting, intake, condensate trap, hose or inducer.
  • Closed with the inducer off: the switch is stuck closed or jumpered.

Taking the reading

  • Tee the manometer into the hose between the inducer (or collector box) port and the switch, so you read what the switch sees.
  • Read it with the inducer at full speed, and on two-stage furnaces at the stage whose switch you're checking (they often have separate low- and high-fire switches).
  • Watch it through a whole cycle on intermittent faults; a draft that fades as the trap fills or in wind tells you more than one reading.
  • Replace a switch only with the exact OEM part or setpoint. A different setpoint changes the safety margin.

Full procedure: furnace pressure switch troubleshooting.