Furnace Pressure Switch Checker
Tee a manometer into the pressure switch hose, run the inducer, and enter what you read along with the setpoint printed on the switch. The checker tells you whether the switch should be closed, so you know whether to replace the switch or go after the vent, trap, hose or inducer.
Find what the board's flash code means in the furnace code charts.
How it decides
- Pressures are compared as magnitudes, since furnace switches are usually printed as negative values (for example −0.65 in. w.c.).
- Draft at or above the setpoint: the switch should be closed. If it's open, the switch (or the hose and port right at it) is the problem.
- Draft below the setpoint: the switch is right to stay open. The cause is upstream: venting, intake, condensate trap, hose or inducer.
- Closed with the inducer off: the switch is stuck closed or jumpered.
Taking the reading
- Tee the manometer into the hose between the inducer (or collector box) port and the switch, so you read what the switch sees.
- Read it with the inducer at full speed, and on two-stage furnaces at the stage whose switch you're checking (they often have separate low- and high-fire switches).
- Watch it through a whole cycle on intermittent faults; a draft that fades as the trap fills or in wind tells you more than one reading.
- Replace a switch only with the exact OEM part or setpoint. A different setpoint changes the safety margin.
Full procedure: furnace pressure switch troubleshooting.
Was this tool useful?
One field tip a week
A short, practical HVAC tip in your inbox every week: diagnostics, charging, airflow and code changes. Free, unsubscribe anytime.
We'll only use your email for the newsletter. Privacy policy.
Related tools
Gas Meter Clocking Calculator
Seconds per meter revolution to furnace input in BTU/h, compared with the rating plate, with the target time to aim for.
µAFlame Signal Checker
Compare a flame sensor microamp reading with the manufacturer's minimum and normal reading for the furnace or control.
SH/SCSuperheat & Subcooling Calculator
Enter your line temps and saturation temps; get superheat and subcooling instantly.
Results are estimates for field reference. Always confirm against the equipment manufacturer's charging chart, installation instructions and local code. Found a problem with this tool? Tell us.