Heat Pump Heating Season Checklist

Heating-mode checks: reversing valve, defrost, auxiliary heat, outdoor coil clearance and heating performance.

Saves on this device as you type. Nothing is sent to us.
Job
Equipment
Controls
Thermostat configured for heat pump (O or B reversing valve)
Reversing valve shifts cleanly between cool and heat
Auxiliary/emergency heat stages on call
Aux heat amps per stageA
Outdoor thermostat / balance point setting confirmed
Defrost
Defrost initiated (test mode or jumper per manufacturer)
Defrost terminates; outdoor fan restarts
Defrost sensor attached and insulated
Unit raised above snow line; drains freely
Outdoor unit electrical
Supply voltage at the disconnectV
Disconnect, whip and conduit in good shape
Contactor contacts not pitted or burnedReplace if pitted
Run capacitor: HERM (rated / measured)µF
Run capacitor: FAN (rated / measured)µF
Compressor amps (RLA on plate / measured)A
Condenser fan amps (FLA / measured)A
Wiring tight; no rubbed or overheated insulation
Heating performance
Outdoor air temperature°F
Return air temperature°F
Supply air temperature (heat pump only, no aux)°F
Temperature rise°F
Discharge/vapor line pressurepsig
Suction pressurepsig
No frost buildup on outdoor coil outside defrost
Notes and recommendations