HVAC Warranty Registration Deadlines by Brand (60 or 90 Days)
On most residential equipment, the difference between a 5-year and a 10-year parts warranty is a form that takes a few minutes to fill out. Miss the window and the customer loses five years of coverage, usually without finding out until a part fails. When that happens, the call comes to the contractor who installed it.
Deadlines by brand
Every figure below comes from the manufacturer's own warranty pages or warranty documents (listed under Sources). Coverage varies by model and series, so check the warranty certificate that ships with the unit.
| Brand | Register within | If registered on time | If not |
|---|---|---|---|
| Carrier | 90 days of installation | 10-year parts, or (if the dealer takes part in Consumer Choice) 5-year parts plus 3-year labor on eligible equipment | 5-year parts, no labor |
| Bryant | 90 days of installation | 10-year standard parts on most products; 10-year unit replacement on select Evolution products | 5 years |
| Trane, American Standard | 60 days of installation | Registered Limited Warranty, typically 10-year parts | Base Limited Warranty, typically 5-year parts |
| Goodman, Amana | 60 days of installation | 10-year parts; unit replacement and longer heat exchanger coverage on qualifying models | 5-year parts |
| Lennox (Merit and Elite) | 60 days of installation (or closing on a new home) | 10-year parts, or 7-year parts plus 3-year labor | 5-year parts |
| Rheem, Ruud | 60 days of installation (or closing on a new home) | 10-year conditional parts, and unit replacement on some models | Base limited parts warranty |
| York | 90 days of installation (or closing on a new home) | 10-year parts; lifetime compressor or heat exchanger on qualifying models | 5-year parts, 10-year compressor, 20-year heat exchanger |
Brand notes worth knowing
- Carrier: the warranty option has to be chosen when the product is registered, and it can only be changed in the first 90 days. The 10-year enhanced coverage applies only to the original homeowner; a later owner gets 5 years.
- Trane: each new product in the system has to be registered on its own. Trane's warranty letters also say claims must be filed within 90 days of the failure date.
- Goodman: its newest warranty chart says online registration isn't required in California, Florida or Quebec, and that warranty terms in Texas and Florida differ. Older Goodman literature lists only California and Quebec, so check the certificate for the unit's install date.
- Lennox: the Dave Lennox Signature Collection comes with 10-year parts coverage without registration; registering adds options. On eligible Merit and Elite products, registering lets the homeowner choose between 10 years of parts or 7 years of parts with 3 years of labor.
- Rheem: the 60 days start at the replacement date on the dealer's invoice, or at closing on a new home. Rheem says the conditional portion isn't transferable; a later owner gets what's left of the base warranty.
- York: registration is at upgproductregistration.com. Three-phase light commercial models carry much shorter parts coverage.
Places where registration isn't required
Several manufacturers say registration isn't required where the law doesn't let warranty benefits depend on it, naming California and Quebec in particular. Carrier says those jurisdictions automatically get the 10-year parts warranty. Registering anyway still helps: it sets the install date on record, which matters when a claim comes in years later.
Why the date matters even after registration
If nobody can prove the install date, manufacturers fall back on the date of manufacture. Rheem's and Trane's warranty documents start coverage from the manufacture date (by serial number) plus 60 or 90 days when the installation date can't be verified. On a unit that sat in a warehouse, that can cost the homeowner months of coverage. Keep the invoice with the model and serial numbers, and register with the real install date.
How contractors keep it from slipping
- Register it yourself, the day of the install. Don't leave it to the homeowner. Trane's own advice to homeowners is not to assume the dealer did it, which tells you how often it gets missed.
- Make it a closing step. Put "warranty registered" on the install checklist next to startup readings, with the confirmation number.
- Give the customer the certificate. Print or email the confirmation. It also shows them you handled something most people never think about.
- Register every component. Outdoor unit, indoor unit or furnace, coil and air handler each have their own serial number. Some brands also require a matched system for the longer terms.
- New construction: watch the closing date. Several brands count from closing, not from when the equipment was set. Coordinate with the builder.
- Keep records. Model and serial numbers, install date, registration confirmation and the customer's contact details. When a failed part comes in years later, the claim goes faster.
Labor isn't the parts warranty
A 10-year parts warranty usually pays for the part, not the trip, diagnosis, refrigerant or labor to install it. Carrier's and Lennox's registration options trade some parts years for a few years of labor coverage on eligible equipment, but only if chosen on time. Anything beyond that is your own workmanship warranty or a separate extended labor plan. Decide in advance what you'll cover and put it in writing; see HVAC maintenance agreements for one way to fund it.
FAQ
What happens if I miss the warranty registration deadline?
On most brands the equipment falls back to the base warranty, usually 5 years of parts instead of 10. Some brands, like Rheem, still encourage late registration, but the base terms may apply.
Is the deadline 60 or 90 days?
It depends on the brand. Carrier, Bryant and York give 90 days. Trane, American Standard, Goodman, Amana, Lennox, Rheem and Ruud give 60. Always check the warranty certificate for the specific unit.
Does the deadline start at installation or closing?
At installation for replacements. For new construction, Lennox, Rheem and York count from the closing date. Check the certificate for other brands.
Do I need to register in California?
Several manufacturers say registration isn't required in California and Quebec (Goodman's newest chart adds Florida) because warranty benefits there can't depend on it. Registering is still a good idea because it records the install date.
Does the warranty transfer if the house is sold?
It depends on the brand, and the enhanced registered terms often don't transfer in full. Carrier's enhanced 10-year coverage is for the original homeowner, and Rheem's conditional portion isn't transferable. Trane offers transfers for a fee if they're completed within 90 days.
Sources
- Carrier: warranty registration and information
- Carrier: warranty lookup (registration not required in California, Quebec and similar jurisdictions)
- Bryant: warranty lookup
- Trane: warranty and registration
- Trane residential warranty letter (registration within 60 days, claims within 90 days of failure)
- Trane / American Standard air handler limited warranty (start date from manufacture date, transfers)
- Goodman: warranty (60-day online registration)
- Goodman product warranty overview chart, PM-WARRCHRT-G 05-25 (California, Florida, Quebec)
- Lennox: warranty and coverage, Warranty Your Way
- Lennox: product warranty eligibility (60 days from installation or closing)
- Rheem limited warranty certificate (60-day registration, RegisterMyUnit.com)
- Rheem limited warranty FAQs (when the 60 days start, transferability)
- York: product warranties (90-day online registration)
- Johnson Controls residential furnace limited warranty 1010352-UUM-J-0818 (90 days of installation or closing)
HVAC Cheat Sheet is published by 90 Leads, a marketing company that works with home service businesses, including HVAC contractors.
Was this guide useful?
One business tip a month
For HVAC shop owners: pricing, marketing, hiring and running a profitable service business. Short and practical. Free, unsubscribe anytime.
We'll only use your email for the newsletter. Privacy policy.
Related guides
How to Compete with Low-Price HVAC Companies
What to do when a competitor quotes far less than you can. Know your break-even, make quotes easy to compare, and win on the things a low price can't cover.
How to Tell the Age of an AC or Furnace from the Serial Number
Decode the manufacture date from Carrier, Bryant, Payne, Trane, Goodman and Lennox serial numbers, where Rheem and York put the date, and what to do when a format doesn't match.
HVAC Maintenance Agreements: How to Build and Sell a Membership Plan
How HVAC maintenance agreements (service plans or memberships) work, what to include, how to price them, and how they smooth out slow seasons.
Offering Customer Financing as an HVAC Contractor
How consumer financing works for HVAC contractors. Covers who lends the money, dealer fees, promotional plans, how to present monthly payments and what to check before signing up.
Field reference for trained technicians. Always follow the equipment manufacturer's instructions, local code and safe work practices. See our editorial standards, or report a correction.